430
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Appendix A
CIP Objects
Dynamix Dual
Measurement Object
This Dual Measurement Object (class code 0x392) defines, in combination
with the selected application type in measurement channel setup, the
additional behavior of the fixed channel pairs.
It provides access to available Dual Channel measurement results and defines
channel pair-specific configuration parameters for differential expansion.
Table 162 - Object Instances
Instance ID
Description
0
Dual Measurement Class Instance
1
Instance 1 for transducer pair 0…1
2
Instance 2 for transducer pair 2…3
Table 163 - Class Attributes
Attribute
ID
Access
Rule
NV
Name
Data
Type
Description of
Attribute
Semantics of Values
1
Get
NV
Revision
UINT
Current object revision.
Current revision.
Table 164 - Instance Attributes
Attribute ID
Access Rule
NV
Name
Data Type
Description of Attribute
Semantics of Values
1
Get
V
SMAX Peak
REAL
Processed SMAX Peak output.
0 output when not an XY
application
2
Get
V
Phase angle of the SMAX Peak
Vector
REAL
Phase angle of attribute 1.
0 output when not an XY
application
5
Get
V
Axial Differential Expansion
REAL
Processed axial differential expansion
output (CDE or Ramp).
0 output when not configured
6
Get
V
Radial Ramp Diff Expansion
REAL
Processed radial differential expansion
output (ramp only).
0 output when not configured
8
Get
V
Shaft Abs Vib Peak
REAL
Processed shaft abs vib pk output.
0 output when not configured
9
Get
V
Shaft Abs Vib pk-pk
REAL
Processed shaft abs vib pk-pk output.
0 output when not configured
Differential Expansion
Group of four configuration attributes.
16
Get
V
Sensor A Ramp Angle
REAL
Ramp angle for sensor input A in
degrees.
Setup information
17
Get
V
Sensor B Ramp Angle
REAL
Ramp angle for sensor input B in
degrees.
Setup information
18
Get
V
Overall Axial Offset
REAL
An overall (axial) offset in DC
measurement units.
Applicable to Ramp and CDE
applications
Range: -50000…50000
19
Get
V
Overall Radial Offset
REAL
An overall (radial) offset in DC
measurement units.
Ramp only
Range: -25000…25000
Содержание 1444-AOFX00-04RB
Страница 10: ...10 Rockwell Automation Publication 1444 UM001D EN P June 2018 Table of Contents Notes...
Страница 12: ...12 Rockwell Automation Publication 1444 UM001D EN P June 2018 Preface Notes...
Страница 198: ...198 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 5 Configure the Tachometer Expansion Module Notes...
Страница 210: ...210 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 7 Configure Relays Notes...
Страница 230: ...230 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 8 Configure Alarms Notes...
Страница 240: ...240 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 9 Trend and Transient Capture Notes...
Страница 316: ...316 Rockwell Automation Publication 1444 UM001D EN P June 2018 Chapter 10 Operate the Module Notes...
Страница 549: ......