PL-9

 User Guide   AP5271 issue 1 

 

 

 

 

  

 

 

 

Introduction

     

The 

PL-9

 is a 7 way PL-Anet hub which extends the 

capabilities of the Allen & Heath 

PL

 

Series

 of wall plates and remote 

controllers.  It can address up to 15 

PL

 devices per branch up to a system 

maximum of 24 depending on the type of devices and distances involved.  
It has a built-in mains power supply to boost the PL-Anet 20V fed down 
each cable to power the devices.  This means that larger systems can be 
created and connected over longer distances.  It can also simplify and 
reduce the wiring required by allowing a ‘star point’ connection scheme.    
In smaller systems the 

PL-9

 can allow individual devices to be connected 

independently to the 

iDR

 audio processor using single cables rather than 

being chained together. 

 A

    

This example shows several 

PL

 devices daisy chained in the normal 

way through the installation.  A maximum of 15 devices may be connected 
on the single PL-Anet feed dependent on their type and distances involved. 

 B

    

This example shows the addition of the 

PL-9

 hub which simplifies the 

cable routing by providing direct feeds to three chains.  It also provides 
more power and addressing allowing  more  than  15  devices  to  be 
connected.  Further 

PL

 devices may be added using the other branches. 

 C

     

This example shows 

PL

 fader controllers each with their own 

connection.  Each may be plugged and unplugged without affecting the 
other.  Up to 7 devices could be independently connected in this way. 

Panel Layouts

 

 1

   

Removable rack ears for 19” rack or desk top operation. 

 2

     

Individual

 

branch status indicators light to indicate that 20V power is 

available over PL-Anet.  Each branch is protected against installation faults 
with a resettable fuse.  The indicator turns off if the fuse has tripped.  
Remove the fault and power down for 1 minute to reset the fuse.  

 3

   

Power and Communication status indicators.  POWER lights when the 

unit is turned on.  CHAIN IN lights when the 

iDR

 or previous 

PL

 device is 

ready to communicate.  CHAIN OUT lights when the 

PL-9 

is ready to 

communicate with its connected 

PL

 devices. 

 4

   

Mains power input with ON/OFF switch, IEC connector and fuse.  Heed 

the warnings printed in this guide and on the rear panel. 

 5

    

PL-Anet input RJ45 socket.  Connects to the end of the PL-Anet chain 

from the 

iDR

 unit. 

 6

   

7x PL-Anet output branch RJ45 sockets A to G.  

 

   

 

 

         

PL-9 Hub for PL-Anet                   

AP5271

 

   

 

 

 

       

User Guide    

PL-9

iDR

PL-9

iDR

iDR

iDR

PL-Anet

 is the proprietary Allen & Heath 

system for daisy chaining remote 
controllers.  It is an RS485 serial connection 
that uses CAT5 STP cable to communicate 
between devices over long distances.  PL-
Anet only works with Allen & Heath 

PL

 

devices.  The port pr20V DC to 
power the connected devices. 