background image

IP1 Getting Started Guide 

Issue 2 

 

IMPORTANT  -  Read before starting 

Safety instructions 

Before starting, read the 

Important Safety Instructions

 

printed on the sheet supplied 

with the equipment.  For your own safety and that of the operator, technical crew and 

performers, follow all instructions and heed all warnings printed on the sheet and on the 

equipment panels. 

 

System operating firmware 

The  function  of  the  IP  Remote  Controller  is  determined  by  the  firmware  (operating 

software) that the mixing system runs. Firmware is updated regularly as new features 

are added and improvements made. 

 Check 

www.allen-heath.com

 for the latest version of mixer or 

AHM firmware. dLive requires firmware V1.60 or higher to work 

the IP1. 

 

Software licence agreement 

By using this Allen & Heath product and the software within it you agree to be bound by 

the terms of the relevant 

End User Licence Agreement

 

(EULA), a copy of which can 

be  found  at 

www.allen-heath.com/legal

.  You  agree  to  be  bound  by  the  terms  of  the 

EULA by installing, copying, or using the software. 

 

Further information 

Please refer to the 

Allen & Heath website

 for further information, knowledgebase and 

technical support. For more information on mixer or AHM processor setup and mixing 

functions  please  refer  to  the  respective  guides  available  for  download  a

www.allen-

heath.com

 

 Check for the latest version of this Getting Started Guide.  

You  can  also  join  our  Allen  &  Heath  Digital  Community  to  share  knowledge  and 

information with other dLive users. 

 

 

 

Содержание IP1

Страница 1: ...IP1 Getting Started Guide Before starting please check www allen heath com for the latest software and documentation Issue 2 ...

Страница 2: ... terms of this warranty may be fulfilled with functionally equivalent service exchange units This warranty is not transferable This warranty will be the purchaser s sole and exclusive remedy and neither Allen Heath nor its approved service centres shall be liable for any incidental or consequential damages or breach of any express or implied warranty of this product Conditions Of Warranty The equi...

Страница 3: ...r or AHM firmware dLive requires firmware V1 60 or higher to work the IP1 Software licence agreement By using this Allen Heath product and the software within it you agree to be bound by the terms of the relevant End User Licence Agreement EULA a copy of which can be found at www allen heath com legal You agree to be bound by the terms of the EULA by installing copying or using the software Furthe...

Страница 4: ...at servicing is carried out only by an authorised Allen Heath agent Contact details for your local distributor can be found on the Allen Heath website Allen Heath do not accept liability for damage caused by maintenance repair or modification by unauthorised personnel Register your product Register your product online at www allen heath com register IP1 Getting Started Guide Copyright 2021 Allen H...

Страница 5: ...n 3 General precautions 4 Register your product 4 Contents 5 Packed items 6 1 Introduction 6 2 Mounting the Remote Controller 7 2 1 IP1 US 7 2 2 IP1 EU 7 3 Front Panel 8 4 Connection and configuration 9 4 1 System connection 9 4 2 Set up the unit Name and IP Address 9 4 3 Reset Network Settings 10 4 4 Programming the Remote Controller 11 5 Dimensions 12 6 Technical specs 14 ...

Страница 6: ...etwork connections and can therefore be networked with other controllers computers and third party devices using standard Ethernet infrastructure It is powered over Ethernet PoE The IP1 controls and functions are programmed using the AHM System Manager software dLive Surface Director software or Avantis mixer Director software and can suit a number of applications including Zone level control Sour...

Страница 7: ... the instructions of the face plate and or wall box for screw specification and mounting IP1 EU This model fits standard UK wall boxes BS 4662 and European wall boxes DIN 49073 with a minimal depth of 30mm and Honeywell MK Elements or compatible plates Refer to the instructions of the face plate and or wall box for screw specification and mounting NEMA single gang wall box Face plate IP1 IP1 IP1 F...

Страница 8: ...on is assigned to the IP1 Rotary Encoder Assignable dual function rotary control Push and turn to control its second function or push to enter Source Select or Scene Preset Select mode Available functions include Input Level Mix Zone Level DCA Control Group Level Aux Send Level FX Send Level Matrix Send Level Source Selector Level Source Pan Scene Preset Select 1 2 1 2 Level bar and meter Channel ...

Страница 9: ...ler is not the same version as that in the mixing system then the host mixer or processor will automatically update the IP firmware at power up Either of the two PoE standards 802 3af 15 4W at source or 802 3at 25 5W at source is suitable Check that the overall power rating is enough to provide for all IP Remote Controllers you wish to connect allow 5W per IP1 unit Set up the unit Name and IP Addr...

Страница 10: ... network settings Repeat the operation for each IP1 unit in the system System software Connect the IP1 and a dLive Avantis AHM Network port to the same PoE network switch Use the mixer touchscreen interface or Director System Manager software to edit the IP1 network settings Once applied repeat the operation for each IP1 unit in the system Refer to the mixer or AHM processor guides available for d...

Страница 11: ...k connection for example the unit might be physically connected to the MixRack but set to link to the Surface Linking to the MixRack provides an independent Remote Controller that can be used with or without Surface connection and is recommended for fixed install applications The functions and assignments of the IP1 are stored in the dLive Avantis Scenes or AHM Presets They are not stored locally ...

Страница 12: ...IP1 Getting Started Guide 12 Issue 2 5 Dimensions 50 00 15 10 50 00 18 80 32 35 ...

Страница 13: ...IP1 Getting Started Guide 13 Issue 2 45 00 31 85 106 00 24 45 15 60 ...

Страница 14: ...umption 2 5W Operating Temperature Range 0 deg C to 35 deg C 32 deg F to 95 deg F Dimensions and Weights Width x Depth x Height x Weight IP1 US 45 x 25 x 106 mm x 0 1kg 3 5 ounces IP1 US boxed 131 x 170 x 90 mm x 0 2kg 7 5 ounces IP1 EU 50 x 32 x 50 mm x 70g 2 5 ounces IP1 EU boxed 131 x 170 x 90 mm x 0 2kg 7 5 ounces ...