4.2 Configuring the controller in IF-6040

In IF-6040 under  Access > Access management > Controller:

1. Select 

Interflex CHP

 under 

Options

 in the 

Transmission protocol

 field

2. Enter the 

serial number

 of the controller under 

Connections

.

3. Select a suitable 

Configuration

 under 

Connections > Peripheral server

.

Suitable: The 

Controller host protocol and firmware update

 option is activated in the

Interfaces

 tab and an enabled port is entered. If required, create a suitable configuration.

4. Under 

Perform action

, select the 

Update controller data on the peripheral server

 menu

item

Detailed information on this subject can be found in the IF-6040 documentation

4.3 Registering the controller

Prerequisites

ü

PKI certificate installed and configured

Service interface

1. In 

IF-6040

 under

 Access > Access management > Controller

: Select 

Perform action >

Register controller

2. Copy the URL of the IF-6040 in the registration window

3. In the 

console

Enroll -u <URL of IF-6040>

4. Copy password in the registration window

5. Command 

enroll -n <password>

Controller is enrolled on IF-6040.

If the controller was already registered once, the second command should be 

enroll -f

.

IF-ServiceApp

To register the controller:

1. Use the USB cable to connect the dongle to the USB port of the controller

The IF-ServiceApp is connected to the controller.

2. Under Access > Access management > Controller menu sequence 

Perform action > Register

controller

3. Make a note of the information on the registration window (URL of the TLS server, registration

password (nonce))

4. In the 

IF‑ServiceApp

, click on the 

Find controller

 in the left menu

5. Select the desired controller to establish a connection

A prompt for the controller password is shown

6. Assign a controller password during the initial login

Содержание interflex IF-5835

Страница 1: ...IF 5835 Time Recording Terminal 00 5835 04xx Terminal...

Страница 2: ...allation site 7 3 2 Fastening the back panel of the housing 8 3 3 Mounting and connecting the PoE connector 10 4 Initial operation 11 4 1 Connecting the controller to the network 11 4 2 Configuring th...

Страница 3: ...IF 5835 Time Recording Terminal 07 22 3 5 6 Tools 21 5 7 Configuring PKI and TLS 25 6 Technical specifications 26 7 Disposal 27 8 Declarations of conformity 28 8 1 UK Declaration of Conformity 28 8 2...

Страница 4: ...cessory bag with mortise lock and fasteners n 95 10430 product info Check the completeness and condition of the goods upon receipt and report any damage caused during transport immediately 1 3 Target...

Страница 5: ...Use suitable mains filters that are professionally installed and operated NOTICE Damage due to electrostatic discharge ESD Electrical components and modules can be damaged by only slight hardly notic...

Страница 6: ...ended cable type 230 V AC power supply to power supply unit if not pre installed NYM 3 x 1 5 mm2 Network cable RJ45 patch cable preferably shield braiding 100 m From category 5 Control cable floating...

Страница 7: ...ting rail power supply unit and fuse protection 4 PoE device Switch or power injector 3 Mounting the terminal 3 1 Installation site NOTICE Damage due to the manipulation of the terminal Manipulation o...

Страница 8: ...rence may occur Thus the following minimum distances must be maintained The minimum distance for back to back installation depends on the nature of the wall in between Please note that all BLE devices...

Страница 9: ...Fasten the back panel of the housing only to an even surface If the cables are surface mounted a spacer 75 5735 00xx is required u Screw the back panel of the housing to the wall through the holes 2...

Страница 10: ...oth screws provided 2 Insert the network cable into the cutout of the metal back panel and plug the RJ45 plug 2 into the socket of the PoE connector 3 Connect the PoE connector to the terminal via the...

Страница 11: ...ions are available for connecting the host computer to the controller Via WLAN with the IF ServiceApp 75 99 0013 Via service interface or USB Service interface USB IF 4xxx controller 75 4070 0001 serv...

Страница 12: ...ssword are the network services started and the network connection can be established Network connection is activated the default setting is DHCP When the RUN LED lights up an SSH connection can be es...

Страница 13: ...d configured Service interface 1 In IF 6040 under Access Access management Controller Select Perform action Register controller 2 Copy the URL of the IF 6040 in the registration window 3 In the consol...

Страница 14: ...e network 3 Logging to the controller 4 Enter the serial number in the ble node list json file in the mnt app folder 5 Reset the controller with facory reset application restart Connecting devices wit...

Страница 15: ...sole 1 2 3 RUN LED DIP switch Reset button 1 2 3 Warm boot A warm boot performs the following actions n Close application n Restart application Associated console command oc s or factory reset applica...

Страница 16: ...eset button 3 Wait until the RUN LED lights up again permanently procedure can take up to 45 seconds 4 Reset switch position Associated console command oc c oder factory reset application Reset networ...

Страница 17: ...d by 2 digits n Does not contain mutated vowels special characters or sequences of characters e g aaa n Does not contain the default password After four consecutive incorrect entries the entry is bloc...

Страница 18: ...g previous log file cloudreadyd 123456 10 log oldest log file Thus the maximum 11 log files use up a maximum of 55 MB of storage script showlog The showlog script lists log files of the CloudReady con...

Страница 19: ...ew and search the log file showlog a Opens the complete current log file of the cloudreadyd service and in the console tool less search possible showlog s a Opens the complete current log file of the...

Страница 20: ...2 2 1 1 Select static IP see above 2 Enter IP address subnet mask CIDR IPv4 address netmask 172 18 70 52 16 3 Enter IPv4 Gateway address IPv4 Gateway 172 18 70 1 4 No DNS server used therefore IPv4 D...

Страница 21: ...the host connections ports etc IFPki exe_custom config The names of the customer certificate and the customer system certificate as entered into the supplied PkiAdministrationTool exe tool Via config...

Страница 22: ...ng that comes before the name it is automatically placed in front of the name New custom system certificate directory Path for exporting the new customer system certificate e g for a later import afte...

Страница 23: ...e g re register all NoM smartphones Interflex thus recommends specifying possible fallback computers Wildcards are also permitted Make a note of the Additional computer names for Tls and save this da...

Страница 24: ...To this end you need the snap in for certificates Installing snap in Install the snap in as follows 1 Open the Windows command prompt DOS box 2 Start mmc exe entermmc 3 With Ctrl M add the Certificate...

Страница 25: ...ice Use the file IFTls exe_custom config on the TLS server Pay attention to the comments in the configuration file Certificates 1 Enter the required certificate name Replace the DummyName entry in cas...

Страница 26: ...viceProxy Run true Name data ChpPkiServiceProxy Run true Name pki ChpLifecheckActionServiceProxy Run true Name action In case of new installations this passage is already integrated They must be manua...

Страница 27: ...eneral data Degree of protection IP30 with concealed wiring Humidity Max 95 non condensing Ambient temperature 4 C bis 40 C Dimensions W x H x D 163 x 87 x 45 8 mm Color Black or white Installation ty...

Страница 28: ...ense information and the links to the OpenSource projects are available for download on the product in the directory home fieldservice app docs Source code and updates are provided in the directory So...

Отзывы: