Allegion 8310-889 Скачать руководство пользователя страница 1

75.5323.01 ALLEGION SAFETY MODULE 8310-889 20180702 

 

Page 1 of 4

1.  DIP swtiches

2.  Red LED (safety)

3.  Green LED (activation)

 1

 2

 3

8310-889 SAFETY MODULE

PRECAUTIONS

75.5323.01 ALLEGION SAFETY MODULE 8310-889 20180702 

 

Page 1 of 4

Lock-out relay

ENGLISH

DESCRIPTION

TECHNICAL SPECIFICATIONS

Power supply:

12 – 24 VAC/VDC

Operating frequency:

4 MHz (microprocessor)

Power consumption:

10 mA at rest; 50 mA max.

Output:

2 SPST relays

Max. voltage (relay contact):

60 VDC / 120 VAC

Max. current (relay contacts):

2.0A DC / 0.5A AC

Specifications are subject to change without 

prior notice.

All values measured in specific conditions.

 

‰

Shut off all power going to header before attempting any wiring procedures.

 

‰

Maintain a clean and safe environment when working in public areas.

 

‰

Constantly be aware of pedestrian traffic around the door area. 

 

‰

Always stop pedestrian traffic through the doorway when performing tests that may result in 
unexpected reactions by the door.

 

‰

ESD (electrostatic discharge)

:  Circuit boards are vulnerable to damage by electrostatic discharge. 

Before handling any board, ensure you dissipate your body’s ESD charge.

 

‰

Always check placement of all wiring before powering up to ensure that moving door parts will not 
catch any wires and cause damage to equipment.

 

‰

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of 
installation.

 

‰

DO NOT attempt any internal repair of the components. Unauthorized disassembly or repair:

1.  May jeopardize personal safety and may expose one to the risk of electrical shock.
2.  May adversely affect the safe and reliable performance of the product resulting in a voided 

warranty.

Отзывы: