All-Power APG3012 Скачать руководство пользователя страница 1

Содержание APG3012

Страница 1: ...www all 3oweramenca com...

Страница 2: ...allation 24 Compliance 26 Specifications 27 General Parts Listing 28 WARNING READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANU...

Страница 3: ...w and business hours at the service center location and the availibility of replacement parts All decisions of All Power with regard to this limited warranty shall be final This warranty gives you spe...

Страница 4: ...ed oil adjustments or other installation and start up costs Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable period of...

Страница 5: ...ns Be sure to retain them for future use WARNING WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED CAUTION CAUTIONS INDICATE A POSSIBILIT...

Страница 6: ...il and fuel Attempting to start the engine without oil will ruin the engine and void the warranty Work in well ventilated area Keep cigarettes flames or sparks away from the work area or where gasolin...

Страница 7: ...engine shutdown If this occurs open exhaust system drain plugs if equipped and allow the gases to dissipate before attempting to restart the generator Use only engine manufacturer recommended fuel and...

Страница 8: ...ed plug where one blade is wider than the other This plug fits in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a quali...

Страница 9: ...lectrical characteristics and rated capacities of the generator Before servicing equipment powered by the generator disconnect the equipment from its power input Keep all electrical equipment clean an...

Страница 10: ...it on or off Any generator that cannot be controlled with the power switch is dangerous and must be replaced Generator Use and Care Make sure the power switch is in its OFF position and disconnect th...

Страница 11: ...ance instructions may create a risk of electric shock or injury Heart Pacemakers WARNING PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN S BEFORE USING THIS PRODUCT ELECTROMAGNETIC FIELDS IN CLO...

Страница 12: ...f the generator frame at its low side For trailer installation the generator should be mounted on the center point of the trailer over the wheels The trailer must be capable of supporting the weight o...

Страница 13: ...safety eye goggles and safety hat Do not alter or adjust any part of the generator that is assembled and supplied by the manufacturer Always follow and complete scheduled engine and generator mainten...

Страница 14: ...included s used make sure to use only UL approved cords having the correct gauge and length according to the following table Nameplate Amps Cord Lengths full load 0 ft 50 ft 50 ft lO0 ft 100 ft 150 f...

Страница 15: ...OwneP_s anu Battery This product does not need a battery 15...

Страница 16: ...3250W Generator Assembly No assembly is required 16...

Страница 17: ...EL iS LEVEL WiTH THE UPPER MARKED LiNE ON THE DiPSTiCK THEN SCREW THE DiPSTiCK BACK iNTO THE OiL FiLL HOLE Before Starting the Generator 1 Check that the engine power switch is in its OFF position 2 B...

Страница 18: ...the fuel tank to the carburetor Be sur to return the fue valve lever to the OFF position after stopping the engine 3 To start a cold engine move the choke lever to the CLOSED position To restart a war...

Страница 19: ...nk the engine i_ ii 5 If the choke lever has been moved to the CLOSED position to start the engine gradually move it to the OPEN position as the engine warms up Stopping Engine 1 Turn the engine switc...

Страница 20: ...ONER generator is running simply connect the power cords of 120 volt AC powered equipment into the 120 volt AC dual outlets NOTE THE GENERATOR FEATURES AN AC NON FUSE CIRCUIT BREAKER TO PROTECT THE AC...

Страница 21: ...CONNECT THE POSITIVE LEAD OF THE POWER CORD TO THE POSITIVE TERMINAL ON THE GENERATOR AND CONNECT THE NEGATIVE LEAD OF THE POWER CORD TO THE NEGATIVE TERMINAL ON THE GENERATOR 3 If using only a 12Vvol...

Страница 22: ...g Discard it if the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused 4 Measure the plug gap with a feeler gauge 5 Check that the spark plug washer is in goo...

Страница 23: ...technition before further use Do not use damaged equipment Before each use make sure the engine s oil and gas levels are adequate If necessary fill the crankcase until the oil level is even with the o...

Страница 24: ...OR HOiSTiNG EQUIPMENT WHEN MOVING iT TO THE iNSTALLATiON LOCATION ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR General Location Make sure to locate and install the generator outdoors where...

Страница 25: ...ach the frame to the concrete slab using 3 8 diameter expansion anchor bolts not supplied Grounding NOTE IT IS RECOMMENDED THAT ONLY A TRAINED AND LICENSED ELECTRICIAN PERFORM THIS PROCEDURE Connect a...

Страница 26: ...ificate This certificate of conformity does not cover small non road engines imported prior to the effective date of the certificate SMALL NON ROAD ENGINE FAMILY 6CDPS This certificate of conformity i...

Страница 27: ...Distributed by ALL POWER AMERICA 2005 ALL POWER AMERICA 16273 E Gale Ave City Of Industry California 91745 www all powe ra me rica co m 46...