APG3004A

1000W 2 STROKE GENERATOR

TM

Owner’s Manual

www.allpoweramerica.com

HAVE QUESTIONS

OR NEED SERVICE

PREGUNTAS O

NECESITA SERVICIO

DO NOT RETURN

TO STORE

888.896.6881

NE PAS RETOURNER

AU MAGASIN

888.896.6881

POR FAVOR NO

REGRESE A TIENDA

888.896.6881

DES QUESTIONS

BESOIN D’UNE RÉPARATION

Содержание All-Power APG3004A

Страница 1: ...nual www allpoweramerica com HAVE QUESTIONS OR NEED SERVICE PREGUNTAS O NECESITA SERVICIO DO NOT RETURN TO STORE 888 896 6881 NE PAS RETOURNER AU MAGASIN 888 896 6881 POR FAVOR NO REGRESE A TIENDA 888...

Страница 2: ...ew Safety Information Specifications Components Starting Your Generator Operating Your Generator Stopping Your Generator Maintenance Storage Statement Trouble Shooting 5 4 3 6 7 6 6 6 8 7 2 1000 WATT...

Страница 3: ...1000 WATT GENERATOR 3 Exploded View 7 8 5 4 1 2 3 6 43 44 45 46 47 48 33 34 35 37 36 38 40 41 39 24 23 22 21 29 28 27 26 25 19 20 15 18 17 16 9 13 12 11 10 14 30 42 31 32...

Страница 4: ...t in loss of consciousness and death See a doctor if you or a member of your family develops cold or flu like symptoms Carbon monoxide poisoning can easily be mistaken for a cold or flu and is often d...

Страница 5: ...rk Plug BSES Governor Mechanical Adjustable Lubrication Forced Air Cooling System 45 X 40 mm Stroke TWO Stroke Carburetor Type Hg63 Air Cleaner Type Sponge element Compression Rate 6 Decibel Ratio 80d...

Страница 6: ...1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 13 13 12 12 11 11 10 10 1 Handle 2 Fuel Cap 3 Fuel Tank 4 Fuel Shut off 5 Recoil Starter 6 Engine On Off Switch 7 Throttle Lever 8 Air Cleaner 9 Control Panel 10 Gen...

Страница 7: ...nect all external electrical appliances before pushing the reset button After reconnecting the external electrical appliance if reset continues to trip that indicates that the electrical lead connecte...

Страница 8: ...crease 6 Cover generator and store in dry well ventilated place STATEMENT 1 For non handheld engines The Emissions Compliance Period referred to on the Emissions Compliance label indicates the number...

Страница 9: ...t Indicator Light off No AC Output Tripped Circuit Breaker Tripped Circuit Breaker Poor Connection or Faulty Lead Poor Connection or Faulty Lead Broken Receptacle Broken Receptacle Faulty Generator Fa...

Страница 10: ...U1 U1 U2 U2 R2 R2 R1 R1 D2 D2 D1 D1 FC2 FC2 FC1 FC1 SC SC MC2 MC2 MC1 MC1 DC DC C C D3 D3 Over Volt Protective Over Volt Protective Resistance Resistance Spin Rectifier Spin Rectifier Rotor Pole Wind...