User Manual
Proxima Semi-Auto Dual Heat Press
Installation
1. Requires air hose with 5mm inner diameter & 8mm outer diameter.
2. Requires air compressor with minimum 1.5kw, 50L hold tank, and 0.7M pa.
Instructions
1. Auto Mode: Heat plate presses automatically when the machine reaches the right or left ends.
Press Auto/Manual switch button to change operating modes.
2. Manual Mode: Press both “Press Buttons” at the same time to heat press.
Control Panel
Press SET button one time to start adjusting the temperature. Press it again to adjust the time. Press it for the
third time to exit the setting interface.
Press and hold SET button to enter the parameter setting interface. Press and hold SET button again or power
off the machine to exit parameter setting interface.
Press this key to increase the corresponding paramater value after the machine enters the parameter setting
interface. Press and hold this key to start self-tuning (°C or °F symbol on the panel will begin blinking). Once the
machine begins self-tuning, do not unplug or press any key until self-tuning has finished (°C or °F symbol stops
blinking).
NOTE: Before applying self-tuning, set temperature to normal working temperature and let the heat plate cool down
to room temperature. Implement self-tuning after changing the heat plate, thermocouple wire, or control panel.
Press this key to decrease the corresponding parameter value after the machine enters the parameter setting
interface.