Alien green Mostat Скачать руководство пользователя страница 1

Instructions for Installation v1.0

Содержание Mostat

Страница 1: ...Instructions for Installation v1 0 ...

Страница 2: ...usage if needed The thermostat must be set up according to current installation standards Before starting the work make sure the boiler is NOT supplied with voltage power USER SAFETY GUIDANCE 01 NOTE The pictures of the printed circuit board of the boiler in the User Safety Guidance give a general idea of its looks while an actual printed circuit board may differ schematically in products of the v...

Страница 3: ...IN THE BOX Temperature and Humidity Transmitter Room Sensor Process Control Block PCB Outside Antenna Antenna Connector 2x AA Batteries Power Cable 2 strand Wire 2x Bolts 02 2x Cable Ties ...

Страница 4: ...eating boiler DEVICE DESCRIPTION 03 Wi Fi router is connected to the Internet and provides the connection between the devices NOT applied to the complexion The temperature and humidity transmitting sensor can be installed in the office or private residence ...

Страница 5: ...er CAUTION Before starting the work please make sure that the boiler is NOT supplied with voltage power Unpack the PCB process control block Open the boiler so that you can reach the printed circuit board If necessary use the instructions for the boiler INSTALLATION 04 ...

Страница 6: ... antenna connector to the process control block PCB 3 Fix another end of the antenna connector in the hole and wrap it around the bolt 4 Screw the antenna to the casing as shown on the picture 2 3 4 Green Lights AP Status Status Red Light of Power Indicator Green Light of Boiler Indicator Button 7 mm 1 05 ...

Страница 7: ... cable is connected to the process control block PCB the red light appears while the green light of is blinking Status 2 strand Wire Power Cable Printed Circuit Board 5 Find the connector for the room thermostat with the number TA1 if you have a boiler by Ariston or TA LS LR COM NO if you have a boiler by any other manufacturer but Ariston Disconnect the connector on TA1 and connect the 2 strand w...

Страница 8: ... If the connector TA1 of process control block PCB is connected properly the boiler flame will appear within 10 seconds The flame will fade when the button on the process control block PCB is pushed again If the boiler flame did not appear swap the strands of TA1 wire and repeat the procedure Button Green Light of Boiler 07 ...

Страница 9: ...plication in the mobile phone and push the button MOSTAT Configuration Using Wi Fi of your mobile phone connect to Mostat device named MOSTAT Serial number of your device If asked for a password type in capital letters and follow the application instructions MOSTAT123 The application will connect the devices to your home Internet QR CODE can also be used for downloading the application ONLINE ACTI...

Страница 10: ... when the device is connecting to Wi Fi router AP Status The green light of is on when the process control block PCB is active Status The green light of is on when the process control block PCB is connected to the Wi Fi router AP Status The green light of boiler indicator is ON when the heating is ON The green light of boiler indicator is OFF when the heating is OFF TA1 Green Lights AP Status Stat...

Страница 11: ... family members spend most of their time The distance between the floor and the device must be 120 150 cm The device must be 200 300 cm away from the door and windows Avoid the sunlight TIP These recommendations are given for avoiding the measurement errors of temperature mostat 120 150 cm 200 300 cm 200 300 cm 10 ...

Страница 12: ...Status During this activity the configuration parameters are exchanged between the process control block PCB and the room sensor After the configuration is successfully completed the green light will blink three times on the room sensor If the configuration is successfully complete push the button again RUN RST Button Light If the configuration is NOT successfully complete push again the button on...

Страница 13: ...Factory Reset on the Process Control Block PCB block PCB for 10 seconds until the and lights start blinking fast Then let the button go and AP Status Status this way the device will be factory reset Open the application on your mobile phone choose Configuration and follow the instructions on your phone Hold down the room sensor button for 10 seconds until How to Perform a Factory Reset on the Room...

Страница 14: ...rature Feeling 0 01ºC Humidity Sensor 0 up to 100 RH Humidity Feeling 0 04 RH Room Sensor 2x AA battaries will run for a year Process Control Block PCB Supplied with power from the central heating boiler Wi Fi Internet connection is mandatory Compatible to 90 of the central heating boilers used in Georgia Thermostat is controlled through applications iOS Android Web Safari Chrome Firefox Communica...

Страница 15: ...mostat faq https aliengreen ge ka contact us https www instagram com mostatge https www facebook com mostatge http twitter com mostatge Whether you need a technical support or simple advices Feel free to contact us Sincerely Alien Green team 14 ...

Отзывы: