Register Period (seconds)
Maximum requested period of time where the 8128 Strobe will re-
register with the SIP server. Default setting is 3600 seconds (1 hour).
Only change if instructed otherwise.
Keep-alive Method
If Double CRLF is selected the 8128 Strobe will send a packet every
30 seconds (unless changed) to maintain connection with the SIP
Server if behind NAT.
Server Redundancy Feature
Two secondary SIP servers may be configured. The 8128 Strobe will
attempt to register with the primary server but switch to a secondary
server when necessary. The configuration allows re-registration to
the primary server upon availability or to stay with a server until
unresponsive.
Backup Server #1
If primary server is unreachable the 8128 Strobe will attempt to
register with the backup servers. If enabled the 8128 Strobe will
always attempt to register with the highest priority server.
Backup Server #2
If backup server #1 is unreachable the 8128 Strobe will attempt to
register with the 2nd backup server. If enabled the 8128 Strobe will
always attempt to register with the highest priority server.
Polling Intervals (seconds)
Time period between sending monitoring packets to each server.
Non-active servers are always polled, and active server may
optionally be polled (see below).
Poll Active Server
Explicitly poll current server to monitor availability. May also be
handled automatically by other regular events, so can be disabled to
reduce network traffic.