9.2.12  AUTOMATIC PROG 

If <ON> is selected in the automatic program, the Timy3 always starts with the program cur-
rently in use (for example Stopwatch). 
This feature is recommended if the user always uses the same program. 

9.2.13  SYNC 

You can re-synchronize the Timy3 in this menu (enter new time of day). 
 

9.3  CHANNELS 

Configuration of the timing channels: 

9.3.1 

INTERNAL 

9.3.1.1 

DELAY 

The delay time of the internal timing channels c0, c1, c2, c3, c4, c5, c6, c7 and c8 can be set. 
Delay time is the time after which the channel is blocked after an impulse, to prevent multiple 
impulses (see point 5.2). 

  <DELAY START C0>  

standard is 1.00 second

 

  <DELAY C1-C8>  

 

standard is 0.30 second

 

  <DELAY C1>   

 

not always available! 

  <DELAY C2> 

  <DELAY C3> 

  <DELAY C4> 

  <DELAY C5> 

  <DELAY C6> 

  <DELAY C7< 

  <DELAY C8> 

9.3.1.2 

0.1s-CORRECTION 

If impulses are transmitted by the TED or an external WTN, the 0.1 seconds delay can auto-
matically be corrected for every channel. This function is not adjustable at the Timy3 when the 
internal WTN is activated as the correction is then automatically activated. 

9.3.1.3 

EDGE 

This is for setting of triggering the impulses either on closing and/or opening. Standard for all 
channels is on closing (falling edge). 

For channel C0, C1, C2, C3,  C4 and C5 the edge is adjustable. You can either set each of 
these 6 channels individual or all together.  

C0 – C5: 

 

impulse when contact is closing (factory setting) 

 

impulse when contact is opening 

 + 

 

impulse when contact is closing and opening

 

    AS TRIGGER 

When  an  impulse comes from the WTN (radio), it is processed 
via the edge in Timy3 and not as a data packet. This is important 
for synchronization. This setting is only available if you adjust C0 
- C5 (not for a single channel).

 

 

You can adjust at the WTN if a timing impulse has an output of the falling edge <EDGE1> 
or of both edges <EDGE2>.

 

 

 

Содержание Timy3 WP

Страница 1: ...Manual General Version E200128...

Страница 2: ...ian according to IEC 60364 1 Never touch the mains plug with wet hands Never touch live parts Cleaning Please clean the outside of the device only with a smooth cloth Detergents can cause damage Never...

Страница 3: ...3 and the other relevant Provisions of the FTEG article 3 R TTE 1999 5 EC Health and safety according to 3 1 1 article 3 1 a Applied harmonized standards EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2...

Страница 4: ...hood D printer hood opener E LCD graphic display F silicon keyboard G carrying band eyelet 1 USB interface 2 charging socket 3 ALGE TIMINGmultiport 4 connection for display board 5 connection for star...

Страница 5: ...chronization Switched Off SYNC OFF 17 4 4 2 Passive Synchronization by WTN PASSIVE 17 4 4 3 Single Synchronization Output ACTIVE 17 4 4 4 Synchronization Output every Minute ACTIVE PER MIN 17 5 Connec...

Страница 6: ...9 6 3 AUTO LINE FEED 27 9 6 4 START LOGO 27 9 6 5 PRINT DAYTIME 27 9 7 PROGRAM 28 9 8 Program Specific Settings 28 9 9 WTN 28 9 9 1 WTN POWER 28 9 9 2 STATE 28 9 9 3 SETTINGS 29 9 9 4 TEAM 29 9 9 5 SO...

Страница 7: ...re proof USB interface The memory of the Timy3 can store up to 30 000 times which can be shown on the display or transmitted to a computer by RS232 or USB interface at any time The integrated radio mo...

Страница 8: ...cen tration clock and infield display board Parallel Diff timing for parallel slalom difference time of both slopes Dual Timer timing of two separate courses Timeout timing with timeout also applicabl...

Страница 9: ...is always visible on the display START ON manual start impulse and switch on the Timy3 STOP OFF manual stop impulse and switch off the Timy3 Printer paper output combination and opens printer menu 2nd...

Страница 10: ...menu Press menu key Select DISPLAY with arrow down key Press OK key red or green Select Back Light with arrow down key Press OK key red or green The display shows ENERGY SAVE external supply display...

Страница 11: ...Finnish and Dutch Press menu key Select GENERAL or ALLGEMEIN with arrow down key Press OK key red or green Select LANGUAGE or SPRACHE with arrow down key Press OK key red or green The display shows di...

Страница 12: ...returns to the pro gram Method 2 Press 2nd and STOP OFF keys Display shows Really switch off Press the red OK button If you press the red OK key within 10 seconds the Timy3 switches off otherwise it...

Страница 13: ...e used NiMH battery pack NM TIMY2 The NiMH rechargeable battery pack is recommended for every Timy3 These newly developed batteries dispose of an enormous persistence even at very low temperatures and...

Страница 14: ...e of Paper for Timy3 WP Design 2 press printer hood opener see picture on the right lift printer hood take out paper axis place the axis inside a new paper roll insert paper roll with axis into Timy3...

Страница 15: ...is displayed in the bottom line the time for your region can be adjusted with keys and As soon as the correct time is shown press Attention After receipt of a valid GPS signal the Timy3 verifies the c...

Страница 16: ...Timy3 by Cable The Timy3 can send a synchronization signal via channel 0 every full minute when using the programs BACKUP or PC TIMER Connect the Timy3 with the device to be synchronized Enter the tim...

Страница 17: ...setting ACTIVE ACTIVE PER MIN 4 4 1 WTN Synchronization Switched Off SYNC OFF Timy3 does not output or read a synchronization time 4 4 2 Passive Synchronization by WTN PASSIVE The Timy3 can read and...

Страница 18: ...start channel C0 1 0 s stop channel C1 to C9 0 3 s 5 2 2 Block Time The block time is the theoretic minimum interval between two valid impulses of the same channel Impulses within the block time are...

Страница 19: ...ng link https alge timing com alge download software IM exe download the file and start the install manager IM exe click on the folder Timy USB connect Timy3 with the USB cable to the PC start Timy3 t...

Страница 20: ...W_SN hardware serial number C0 C3 channel number is here if the channel is not triggered When the channel is triggered the channel number and a black bar appear alternately PRI INT Timy with printer P...

Страница 21: ...on and mode for calculation of times The bold printed setting is the factory setting 9 2 1 1 PRECISION This is for setting the calculation precision Only for net times 1s calculated times in seconds 1...

Страница 22: ...owing languages as defaults for the Timy3 GERMAN ENGLISH FRENCH ITALIAN SPANISH FINNISH DUTCH SWEDISH 9 2 6 STANDARD Reset the Timy3 to the factory defaults STANDARD SETT 9 2 7 HARDWARE This menu is o...

Страница 23: ...impulses are transmitted by the TED or an external WTN the 0 1 seconds delay can auto matically be corrected for every channel This function is not adjustable at the Timy3 when the internal WTN is ac...

Страница 24: ...OFF Factory default ON ATTENTION If this function is activated the serial interface is occupied by the TED 9 3 4 CHANNEL PATTERN In this menu each single channel can be permanently activated or deact...

Страница 25: ...ton during timing operation the bottom line of the display shows C0 C1 C2 FIX With pressed 2nd button and F3 the display can be changed in order to permanently show the channels With the arrow buttons...

Страница 26: ...on 9 4 4 3 AUTOMATIC Backlight is switched on for 5 seconds with each keystroke and timing impulse 9 5 INTERFACE Settings for the RS232 and scoreboard interface Some settings are only available in cer...

Страница 27: ...no longer available TEL NR 1 input of the phone number that it dials TEL NR 2 input of the 2nd phone number that it dials SMS MAX PAK CONFIG 9 6 PRINTER This menu is for setting the printer parameter...

Страница 28: ...could lead to the loss of timing impulses during the first 5 minutes In this menu item the WTN specific settings can be executed further explanations see also Manual WTN A Timy2 with an external WTN...

Страница 29: ...ed only for ALGE factory settings 9 9 4 TEAM Settings of the team 1 9 A F see also Manual for WTN 9 9 5 SOCKET It is possible to configure nine timing channels in this mode for the WTN Impulses taken...

Страница 30: ...essages show up on the display These messages inform the operator about problems or unusual operating conditions 10 1 Long Time Timing Impulse If the Timy3 receives a very long or endless timing impul...

Страница 31: ...channels RS232 PC connection display board RS485 network power supply 8 22 VDC in 7 5 21 VDC out USB 1 power supply 8 22 VDC in 2 Radio module WTN 2 4 GHz band integrated with 16 adjustable frequencie...

Страница 32: ...3 precision 1 10 000 s 5 c7 timing channel 7 precision 1 100 s 6 data output for display board 7 RS485B 8 RS485A 9 clock for terminals CLK 10 RS232 TX 11 RS232 RX 12 common ground GND 13 stabilized vo...

Страница 33: ...rt channel C0 5 banana plugs for stop channel C1 6 Photocell socket 7 Pin assignment 1 c0 start channel 2 c1 stop channel 3 GND common ground 4 Ua power supply out 8 22 VDC only on external supply 5 5...

Страница 34: ...gure is blank or info see below x blank NNNN start number max 4 digit any pre zero is not shown CCC channels of timing device c0 channel 0 start channel c0M channel 0 triggered by keypad START c1 chan...

Страница 35: ...Manual Timy3 General 35...

Страница 36: ...Manual Timy3 General 36...

Страница 37: ...CR channel C2 1 intermediate time NNNBxxxxHH MM SS zhtRR CR channel C3 2 intermediate time NNNExxxxHH MM SS zhtRR CR channel C4 3 intermediate time NNNFxxxxHH MM SS zhtRR CR channel C5 4 intermediate...

Страница 38: ...Manual Timy3 General 38...

Страница 39: ...Manual Timy3 General 39...

Страница 40: ...Manual Timy3 General 40 Subject to changes and misprints Copyright by ALGE TIMING GmbH Rotkreuzstr 39 6890 Lustenau Austria www alge timing com...

Отзывы: