background image

Manual 

TIMY3 – Jumping 

 

 

Page 7 

1.  Athlete starts on a socket next to the mat, hands on hip, and jumps down onto the mat. 
2.  On landing on the mat, the athlete jumps up as high as he can. 
3.  The TIMY3 measures the contact time and the fly time. 
 

Printer Output: 

 

 

0003 C0    13:41:02.1706 

time of day when jump happens 

     Drop     0.3483 con 

time on the mat 

     Drop     0.5134 fly 

time in the air

 

     Drop         32 cm  

jumping height

 

4.4  Power Test 15s, 30s and 60s 

This test measures how many jumps the athlete can execute in  a certain period. The printer 
outputs the time on the mat, the time in the air and the jump height for each jump. 
 
1.  Athlete starts on the mat and jumps as often as he can until the interval is elapsed. 
2.  The TIMY3 measures the fly time and the contact time between each jump. 
 

Printer Output: 

  

0005 C0    13:53:11.1796 

time of day when jump happens 

   1 Pow15    0.5134 fly 

1

st

 jump, power test for 15 sec., time in the air 

   1 Pow15        32 cm  

1

st

 jump, power test for 15 sec., jumping height

 

   2 Pow15    0.3572 con 

2

nd

 jump, power test for 15 sec., time on the mat

 

   2 Pow15    0.6208 fly 

2

nd

 jump, power test for 15 sec., time in the air

 

   2 Pow15        47 cm  

2

nd

 jump, power test for 15 sec., jumping height

 

   3 Pow15    0.3572 con 

3

rd

 jump, power test for 15 sec., time on the mat

 

   3 Pow15    0.6079 fly 

3

rd

 jump, power test for 15 sec., time in the air

 

   3 Pow15        45 cm  

3

rd

 Jump, Power Test for 15 sec., jumping height

 

Interface for Display Board 

Output format:

 

1 start-bit, 8 data-bit, no parity-bit, 1 stop-bit 

Bit rate:

 

factory setting 2400 baud (necessary for 

ALGE-TIMING

 GAZ display board) 

 

2400, 4800, 9600, 19200, 28800, 38400 

Transmission protocol:

  ASCII 

 
You can see the number of attempts and the height in cm on the display board. 
The best height can be shown on address “A”. 
 
Each line ends with a carriage return (CR) 
 

Output by RS232 or USB for power test 15 seconds: 

 

12345678901234567890123456 

character counter 

 0008 C0  16:04:13,1768 00 
 0008 Pow15  0,4736 fly 01 
 0008 Pow15     028 cm  01 
 0008 Pow15  0,9523 con 01 
 0008 Pow15  0,5084 fly 02 
 0008 Pow15     032 cm  02 
 0008 Pow15  0,9761 con 02 
 0008 Pow15  0,4564 fly 03 

Содержание Timy 3

Страница 1: ...Manual Jumping Version E190118 ...

Страница 2: ...rician according to IEC 60364 1 Never touch the mains plug with wet hands Never touch live parts Cleaning Please clean the outside of the device only with a smooth cloth Detergents can cause damage Never submerge in water never open or clean with wet cloth The cleaning must not be carried out by hose or high pressure risk of short circuits or other damage Liability Limitations All technical inform...

Страница 3: ...basic requirements of R TTE 1999 5 EC Telecommunication TC terminal device Short Range Device Applied harmonized standards EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 EMC EN301 489 17 v2 1 1 2009 05 v2 2 1 2012 09 EN 300 328 v1 7 1 2006 10 v1 9 1 2015 02 EN 55022 2010 AC 2011 EN 55024 2010 A1 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 Additional Information The product herewith complies with t...

Страница 4: ...t Jump 5 4 2 Counter Movement Jump 6 4 3 Drop Jump 6 4 4 Power Test 15s 30s and 60s 7 5 Interface for Display Board 7 1 Control Elements 1 USB interface 2 charging socket 3 ALGE TIMING multiport 4 connection for display board 5 connection for start emitter C0 6 connection for finish emitter C1 7 standard ALGE TIMING photocell socket ...

Страница 5: ...ng The TIMY3 program JUMPING measures the height of the jump when using a contact mat The contact mat is connected to channel 0 C0 at the TIMY3 1 Connect the contact mat to the TIMY3 channel C0 2 Start the TIMY3 and select program Jumping 3 Select the jumping mode with the function key F0 F1 F2 F3 3 a F0 select further jumping modes 3 b F1 F2 F3 select the mode that is specified above it 4 Jumping...

Страница 6: ...nalysis It helps to test the ability of concentric force of jump muscles a backswing down is allowed The measurement is the same as for squat jump but the movement of the athlete is different In this case the jump is normally designed from the base position standing on a contact mat the arms are placed on the hips and should not be involved in the backswing The goal is to jump as high as possible ...

Страница 7: ... jump power test for 15 sec jumping height 2 Pow15 0 3572 con 2nd jump power test for 15 sec time on the mat 2 Pow15 0 6208 fly 2nd jump power test for 15 sec time in the air 2 Pow15 47 cm 2nd jump power test for 15 sec jumping height 3 Pow15 0 3572 con 3rd jump power test for 15 sec time on the mat 3 Pow15 0 6079 fly 3rd jump power test for 15 sec time in the air 3 Pow15 45 cm 3rd Jump Power Test...

Страница 8: ...w15 043 cm 06 0008 Pow15 1 1634 con 06 0008 Pow15 0 4892 fly 07 0008 Pow15 029 cm 07 0008 Pow15 1 0877 con 07 0008 Pow15 0 5328 fly 08 0008 Pow15 035 cm 08 0008 Pow15 1 1974 con 08 0008 Pow15 0 5273 fly 09 0008 Pow15 034 cm 09 0008 Pow15 1 2228 con 09 0008 Pow15 0 4756 fly 10 0008 Pow15 028 cm 10 Each line ends with a carriage return CR Subject to changes Copyright by ALGE TIMING GmbH Rotkreuzstr ...

Отзывы: