Manual
TdC 8001
-40-
5 Main Menu – General Settings
If settings are changed in the main menu, most of the changes are stored even after turning off. Settings
of the main menu apply for all programs.
5.1 Restoring the Default Settings
−
Turn device off (switch g)
−
Keep <ALT> and <MENU> pressed.
−
Turn device on (switch g)
−
After 5 seconds let go of <ALT> and <MENU>
−
The default settings are active once more.
Settings of the main menu can be inquired and edited via RS232 interface (see chapters 8.2.1, 8.2.2).
5.2 Open Main Menu
−
Select program
−
Press <ALT> and <MENU> at the same time.
−
You can browse the menu with
and
. Directly select any sub program with the numberic
keys of finish keypad (8).
−
Enter the displayed menu with <YES>.
5.3 Main Menu – Brief Description
Menu
1
(p. 41)
: ....... Delay time start = 1.00 s ..................Adjustable: 0.01 to 9.99 seconds
Menu
2
,
(p. 41)
...... Delay time finish = 0.30 s .................Adjustable: 0.01 to 9.99 seconds
Menu
3
,
(p. 41)
: ...... Seconds mode = OFF ......................Adjustable: ON or OFF
Menu
4
,
(p. 41)
: ...... Display time 1 = 03 s ........................Adjustable: 0 to 99 seconds
Menu
5
,
(p. 42)
: ...... Display time 2 = 03 s ........................Adjustable: 0 to 99 seconds
Menu
6
,
(p. 42)
: ...... Display thousandth = OFF ...............Adjustable: ON or OFF
Menu
7
,
(p. 42)
...... Info display = START .......................Adjustable: START, FINISH or OFF
Menu
8
,
(p. 42)
: ...... Running time = RUN ........................Adjustable: RUN or TOTAL
Menu
9
,
(p. 42)
: ...... Running tenth = OFF .......................Adjustable: ON or OFF
Menu
10
,
(p. 43)
: .... Intermediate time rank = ON ............Adjustable: ON or OFF
Menu
11
,
(p. 43)
: ..... Run time rank = ON .........................Adjustable: ON or OFF
Menu
12
,
(p. 43)
: .... STNO automatic = OFF ...................Adjustable: START, FINISH or OFF
Menu
13
,
(p. 43)
: .... Automatic time = 00:00:00.00 ..........Adjustable: any odd time
Menu
14
,
(p. 43)
: .... Print start time = OFF .......................Adjustable: ON or OFF
Menu
15
,
(p. 43)
: .... Print menus = ON ............................Adjustable: ON or OFF
Menu
16
,
(p. 44)
: .... Printer linefeed = 0 ...........................Adjustable: 0 to 9
Menu
17
,
(p. 44)
: .... RS-232 baud rate = 9600 Bd ...........Adjustable: 2400, 4800 or 9600 baud
Menu
18
,
(p. 44)
: .... RS-232 run time = OFF ....................Adjustable: ON or OFF
Menu
19
,
(p. 44)
: .... D-Board baud rate = 2400 Bd ..........no function yet
Menu
20
,
(p. 44)
: .... D-Board channel 2 = RUNNING ......Adjustable: RUNNING or STANDING
Menu
21
,
(p. 44)
: .... Beep = ON .......................................Adjustable: ON or OFF
Menu
22
,
(p. 45)
: .... Handicap time = 00:00:00.00 ...........Adjustable: enter handicap time
Menu
23
,
(p. 45)
: .... Groups = OFF ..................................depending on number of entered groups
Menu
24
,
(p. 45)
: .... Change heat .....................................Adjustable: SAME or NEXT
Menu
25
,
(p. 45)
: .... Change race .....................................changing to another race possible
Menu
26
,
(p. 45)
: .... D-Board-test = OFF .........................test program for display board
Menu
27
,
(p. 46)
: .... ID channel 4 = b (blue) .....................Adjustable b (blue) or L (left)
Menu
28
,
(p. 46)
: .... Penalty time = 1.500 s .....................Adjustable: 0.000 to 9.999
Menu
29
,
(p. 46)
: .... Start channel = SEPARATE .............Adjustable: SEPARATE or COMMON
Menu
30
,
(p. 46)
: .... Rank calculation = SEPARATE ........Adjustable: SEPARATE or COMMON
Menu
31
,
(p. 47)
: .... Print times = ON ...............................Adjustable: ON or OFF
Menu
32
,
(p. 47)
: .... Distance = 100 m .............................Adjustable: 1 to 9999 m
Menu
33
,
(p. 47)
: .... Measuring unit = km/h ......................Adjustable: km/h, m/s or mph
Menu
34
,
(p. 47)
: .... Minimum speed = 10 km/h ...............Adjustable: 1 to 9999
Menu
35
,
(p. 47)
: .... Maximum speed = 200 km/h ............Adjustable: 1 to 9999
Menu
36
,
(p. 48)
: .... Penalty points = 4.00 .......................Adjustable: 0.01 to 99.99