ALGE-Timing D-LINE Series Скачать руководство пользователя страница 10

 Manual 

D-LINE

 

 

1.4 

Extended Datamode 

In this mode you can assign each digit one byte out of the datastring. 
It is for example possible to program it so that you can see on one 6-digit scoreboard the BIB on the 
first 2 digits and the time in m:ss on the last 3 digits. 
In some sports like equestrian (with the Timer S4) you have to program the display for the points in 
this mode. 

1.4.1  Timer S4, Points Showjumping 

Configuration of a 6-digit display in order to show the points, sent by a Timer S4 (equestrian) in the 
middle of the display. 
 
The datapackage of the Timer S4 looks as desribed below: 

1  2  3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

PZ  PE     . 

  

  

  

   H  H 

M

M

S

S

  

   Pz  Pe  CR    

PZ  PE       

  

  

  

   H  H 

M

M

S

S

t  Pz  Pe  CR    

 
 
The parameters should be adjusted like this: 

 

Extended protocol, 2400bps  [A1-40] (S-E2) 

 

Device adress 00 [A3 00] (A-00) 

 

 

First digit is always inactive [A5-00] 

 

Dot or double-dot after first digit is always inactive [A6-00] 

 

Second digit will display points PZ [A7-01] 

 

dot or double-dot after second digit is always inactive [A8-00] 

 

Third digit will display points PE [A9-02] 

 

Will show the dot which is sent after the full second [B0-17] 

 

Fourth Digit will show points Pz [B1-21] 

 

Dot or double-dot after fourth digit is always inactive [B2-00] 

 

Fifth digit will show points Pe [B3-22] 

 

Dot or double-dot after fifth digit is always inactive [B4-00] 

 

Sixth digit is always inactive [B5-00] 

 
In the older Models of the D-LINE, the first digit is A5 and then it is continuing with A6-A9, after 
A9 it starts with B0…. 

Page 10 

 

 

Содержание D-LINE Series

Страница 1: ...Manual Version E070920...

Страница 2: ...Manual D LINE Page 2...

Страница 3: ...l interface setting A1 S 8 1 3 15 Time out for daytime A2 9 1 3 16 Address Setting A3 A 9 1 4 Extended Datamode 10 1 4 1 Timer S4 Points Showjumping 10 1 4 2 TdC8001 Points Showjumping 11 1 4 3 Fixed...

Страница 4: ...shall be in a way that the user can already see by the name of the parameter that he is adjusting the parameter he would like to adjust On the side there shall be also a sticker with a short explanat...

Страница 5: ...eter you can adjust the offset to GMT i9n minutes 1 3 12 Area settings for temperature and time Area parameter in order to adjust the diplaymode for time and temperature Following settings are possibl...

Страница 6: ...mode and temperature in Celsius 1 3 12 2 4 Celsius and 12h x1 Time in 12h mode and temperature in Celsius but on 6 Digit D Line time is centered and without running seconds 1 3 12 2 5 Fahrenheit and 2...

Страница 7: ...ted 1 3 13 2 Second Digit of Setting This setting is defining the brightness mode of the display 1 3 13 2 1 Manual setting The second digit of the brightness setting can be adjusted from 0 to 9 for ma...

Страница 8: ...1 5 Extended Mode 4x This is an advanced mode where you can configure the complete scoreboard by yourself You can define which byte shall be shown on which position of the display board If the serial...

Страница 9: ...rameter described from point 1 3 1 to point 1 3 12 2 7 are not visible anymore If you set this time to 0 the Time Temp Date function is disabled Up to Version 3 7 it is in seconds andfrom Version 3 8...

Страница 10: ...3 24 PZ PE H H M M S S z Pz Pe CR PZ PE H H M M S S z h t Pz Pe CR The parameters should be adjusted like this Extended protocol 2400bps A1 40 S E2 Device adress 00 A3 00 A 00 First digit is always in...

Страница 11: ...is always inactive A8 00 Third digit will display points PE A9 02 Will show the dot which is sent after the full second B0 17 Fourth Digit will show points Pz B1 21 Dot or double dot after fourth dig...

Страница 12: ...Stopwatch and Countdown 2 1 1 2 mm ss zh A1 1x Timeformat for Stopwatch and Countdown 2 1 1 3 Adjusting the Countdown time After you have reached the Countdown mode by pressing the manual button for...

Страница 13: ...lue 3 Technical Data 3 1 Dimensions Type Amount of digits Figure Height Height Width Deep Hangers max Dist Power W D LINE57 I 3 E0 3 57 130 400 60 200 25m 10 D LINE57 I 4 E0 4 57 130 400 60 200 25m 11...

Страница 14: ...onnections Internal button to change the display mode Amphenol Socket 1 10 to 12 Volt 2 Ground 3 Data Out E Data In Connection for manual button Stopwatch Countdown Data In and Ground 100 240V 50 60Hz...

Страница 15: ...E TdC 4000 Identifier for ending time at fourth digit D ALGE TdC 4000 Identifier for total time at fourth digit K Comet 1 Start channel 2 Start channel 4 Stop channel or 8 Stop channel Tc Timer identi...

Страница 16: ...Manual D LINE Page 16...

Страница 17: ...Manual D LINE Page 17 3 3 2 RS485 This interface is optional available with customized protocols 3 3 3 Ethernet This interface is optional available with customized UTP Protocol...

Страница 18: ...Manual D LINE Page 18 4 Comments...

Страница 19: ...Manual D LINE Page 19...

Страница 20: ...Manual D LINE Page 20...

Отзывы: