background image

 

 

THE TASK PURPOSE OF THIS MANUAL  

 
The purpose of the instructions is to enable the user to take all the necessary measures in order to ensure safe and proper 

use of the stove.  

 

 

UPDATING THE INSTRUCTIONS  

This manual reflects a work of art at the moment when the stove was placed on the market. Therefore, Alfa Plam does not 

take into account the stoves that are already on the market with the appropriate technical documentation and considers them 
as defective or inadequate after any kind of modification, adaptation or application of new technologies to newly produced 
machines.  

The contents of this manual should be carefully read and studied. It is necessary to strictly follow all the instructions given 

in this manual. All information contained in this manual is necessary for proper connection, use, and maintenance of your 
stove.  

Therefore, this manual has to be carefully stored for the necessary instructions in the event of any problems or concerns.  
If the stove is given or sold to another person, the new owner must also be given this instructions manual.   
If you have lost your manual, the manufacturer can provide you with a new one.  
 

 

RESPONSIBILITIES OF THE MANUFACTURER  

 
In issuing these instructions, Alfa Plam accepts no civil or legal liability, direct or indirect, due to:  
- Accidents caused by not respecting the standards and specifications given in this manual,  
- Accidents caused by improper handling or use of the stove by the user,  
- Accidents resulting from modifications and repairs, which were not approved by Alfa Plam, 
- Poor maintenance,
  
- Unforeseen events,  
Accidents resulting from the use of spare parts that were not original or not intended for these models of stoves.  
Responsibility for connecting is fully assumed by the installer - contractor.  
 

 

GENERAL CHARACTERISTICS OF USERS  

The user of the appliance must have the following basic characteristics:  
- be an adult and responsible person,  
- have a specific technical knowledge that is needed for routine maintenance of electrical and mechanical components of 

the stove.  

CHILNDREN ARE NOT ALLOWED NEAR THE STOVE OR TO PLAY WITH IT WHILE IT IS ON.  
 

 

TRANSPORTING AND USING THE STOVE - HANDLING  

When using the stove, it is necessary to be careful and not allow the stove to tilt forward. This is because the brunt of the 

stove is forward.  

During transportation of the stove, which has to be completely safe, make sure that the forklift has the load that is greater 

than the weight of the stove that it is supposed to lift. Avoid twitching and jerking movements.  

ALL PACKAGING SHOULD BE REMOVED SO THAT IT IS OUT OF REACH OF CHILDREN, BECAUSE THE MATERIALS THAT 

ARE INSIDE CAN LEAD TO CHILDREN SUFFOCATING. THESE INCLUDE PLASTIC BAGS, FILM, POLYSTYRENE, ETC.  

 

 

RESPONSIBILITIES OF THE INSTALLER   

Installer's  responsibility  is  to  do  all  the  tests  of  the  flue  pipeline,  air  supply,  and  all  the  things  that  are  necessary  for 

connecting (installing) your stove. 

Installer's responsibility is to adjust the stove to local regulations which apply where the stove is connected (installed).  
The use of the stove must be in accordance with the instructions for use and maintenance, as well as with all the security 

standards that are given by the local regulations that apply where the stove is connected (installed).  

The installer has to check:  
-  the type of stove to be connected,  
- whether the room corresponds to the stove where the stove will be installed, which is expressed as the minimum size 

required for installation, set forth by the manufacturer of the stove,  

- heat generator 
- manufacturer's instructions regarding the requirements of smoke removal systems (ducts and pipes for 
  smoke exhaust),  
- inner cross section of the chimney, the material out of which the chimney is made, uniform cross section,  
- that there are no disturbances and obstacles in the chimney,  
- height and vertical extension of the chimney,  
- altitude at the place of connecting the stove,  
- the existence and suitability of the protective cover for the chimney that is resistant to the wind,  
- the possibility of securing the external air supply and the size of the necessary openings,  
- simultaneous use of stove that needs to be connected with other equipment that already exists at that  
   place.  
If  the  results  of  all  checks  are  positive,  then  we  can  proceed  with  connecting  the  stove.  Make  sure  you  follow  the 

instructions of the manufacturer of the stove, as well as the standards for fire protection and the safety standards provided.  

When you are finished connecting, the stove has to be turned on in trial mode for at least 30 minutes to test if the stove is 

working properly.  

When the installation and important details are completed, the installer must provide the client the following:  

Содержание DINO 27

Страница 1: ...uel from timber biomass biofuels INSTRUCTIONS FOR CONNECTING OPERATION AND MAINTENANCE OF THE STOVE This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollut...

Страница 2: ...bustion of the pellet in the stove emits the same amount of carbon dioxide CO2 which would be freed as a result of the natural decay of wood The amount of carbon dioxide CO2 obtained through combustio...

Страница 3: ...g h 11 Degree of efficiency at maximum power 93 5 12 Minimum stove power radiation of water included 8 4 kW 13 Radiation stove power at minimum power 1 kW 14 The power of a water heater at minimum pow...

Страница 4: ...NG AND MAINTENANCE for employees who do maintenance 10 SPECIAL MAINTENANCE 10 IMPORTANT SAFETY INFORMATION 10 THE PELLET QUALITY IS VERY IMPORTANT 11 STORING THE PELLET 11 CONNECTING THE HYDRAULIC INS...

Страница 5: ...rd This is because the brunt of the stove is forward During transportation of the stove which has to be completely safe make sure that the forklift has the load that is greater than the weight of the...

Страница 6: ...wood e g beams or other combustible material located near the stove should be protected covered with fireproof material Leave enough clearance for maintenance work If the stove is installed in a kitc...

Страница 7: ...o 15 x 15 cm or a diameter of up to 15 cm and if there is a cover for checking and cleaning If the chimney has a larger cross section than 15x15cm or a diameter greater than 15cm a possible increased...

Страница 8: ...r cleaning the ashes is completely sealed and to seal it after each cleaning Please make sure everything is properly returned to its place and check the condition of the seals Figure 2a Cleaning eleme...

Страница 9: ...id for cleaning plug in SMER DIMA NE DA Figure 7 Mounting the flue pipe Insulation thickness mm Diameter of the smoke exhaust pipe mm D 80 D 100 Diameters of the holes holes to be made mm The walls ar...

Страница 10: ...This hole must be made on the outer wall of the room where the stove is located The supply of combustion air from the garage a warehouse for combustible materials or from a room where there are risks...

Страница 11: ...uld be cold and that the ashes should be cold as well They need to make sure the handles are cold as well NEVER TURN THE STOVE ON if there is just one of the safety devices that is defective improperl...

Страница 12: ...sive cleaners for cleaning the surface of the stove ROUTINE CLEANING AND MAINTENANCE DONE BY THE USER OF THE STOVE Use a drum shaped vacuum cleaner that can facilitate cleaning the stove The vacuum cl...

Страница 13: ...pulling the mechanism button a few times back and forth you will clean the chamber Do not worry if the mechanism moves slowly if it scratches or gets caught This is how it cleans the chamber Clean th...

Страница 14: ...er burning two tons of pellets Make sure the stove and the ash are cool The smoke channel chimney is resistant to wind and has to be checked and cleaned every year best at the beginning of the heating...

Страница 15: ...poor performance of the stove in case of use of the pellets of inappropriate quality STORING THE PELLET The pellets must be kept in a dry place that is not very cold Cold and moist pellets at the temp...

Страница 16: ...e looking at the stove The output safety valves whose connection protrudes through the rear wall above the pressure line should be put into the sewer pipes CIRCULATION PUMP A high quality Wilo RS 25 6...

Страница 17: ...out water It must be tied to the installation to which the consumers are connected radiators with minimum power of 8 kW PRACTICAL INSTRUCTIONS AND TIPS FOR THE USE OF THE HEATING SYSTEM All connection...

Страница 18: ...etting up and use simple and direct user functions reliable and flexible functional software specially developed for pellets burning appliances advanced features available to installers for adapting s...

Страница 19: ...oes into Standby mode LED symbols Igniter LED is on Igniter is on Auger LED is on Auger is active Pump LED is on Pump is active L3 Aux 1 output LED is on Aux 1 output is activated L4 Additional engine...

Страница 20: ...till in the ignition stage The system will stop working only when it enters the Run Mode Link Error This message informs you that there is no communication between the LCD display and the controller o...

Страница 21: ...buffer and other heating parameters Chrono Menu for selecting chrono program mode and boiler on off times Manual Load Menu for manual loading of the auger It is only feasible when the system is in the...

Страница 22: ...alues of the fan speed of the flue gas fans will be increased by 15 compared to the factory values Factory settings U03 1000 U04 1200 U05 1400 U06 1600 U07 1800 U11 900 Calibrated values U03 1150 U04...

Страница 23: ...e stove is set for precisely determined periods of time It contains two submenus Modality Programming Modality By entering the Chrono menu two submenus appear namely Modalities and Programming Via P4...

Страница 24: ...s that can be chosen Daily program the week day is selected and the system on and off times are programmed There are three time ranges for each day Weekly program system on off times are programmed fo...

Страница 25: ...n 3 seconds After that you can find the following functional conditions of the stove Check Up In the check up stage the initial check of the input signals of the stove and the correctness of the probe...

Страница 26: ...set water temperature it goes into modulation and continues to increase the water temperature by inertia up to the value 4 C higher than the set water temperature in the boiler 2 When an external roo...

Страница 27: ...for more than 3 seconds Contact a service Flue gas fan works at speed different than set Er11 Clock error Problems with internal clock Press and hold the P2 button for more than 3 seconds Check the ac...

Страница 28: ...itch on the back side of the stove and on the control panel the motherboard FLUE GASES FAN If the fan stops the motherboard immediately blocks the supply of pellets and an alarm signal will show GEAR...

Страница 29: ...throwing away or disposing of an old used stove is the sole responsibility of the owner The owner of the stove must abide by the regulations in his her country related to the safety and environment p...

Страница 30: ...was due to too much or too low voltage as well as due to force majeure Malfunctions of the appliance can be removed outside the warranty period with original spare parts that we also give a warranty f...