background image

25 

 

It worked for a 
couple of minutes 
but then it turned 
off. 

1. The ignition phase is not over. 
2. Check if there is an electricity interruption. 
3. The smoke channel is clogged. 
4. Interference of failure of the pressure switch. 
5. The spark plug is damaged. 

1. Try igniting again. 
2. See last instruction. 
3. The smoke channel is clogged. 
4. Check or change the probe. 
5.
 Check or change the spark plug. 

Wooden granules 
are settling in the 
combustion 
chamber.
  
The glass on the 
door is dirty and 
the flame is weak. 

1. Lack of air for combustion. 
2. Wet or inadequate wooden granules. 
3. The smoke vacuum system motor is defective. 
 

1. Clean the combustion chamber and check if all 
the openings are clear. Do the standard cleaning of 
the combustion chamber and the smoke channel. 
Check if air flow is clogged. Check the gaskets on 
the door.  
2. Change the type of the wooden granules. 
3. Check the motor and change if needed. 

The smoke 
vacuum motor is 
defective. 
 

1. The stove is not receiving the electricity. 
2. The motor is defective. 
3. Motherboard is defective. 
4. The control panel is defective. 
 

1. Check the main power supply and resistance to 
melting. 
2.  Check  the  motor  and  condenser;  change  if 
needed. 
3. Change the electronic card. 
 4. Change the control panel. 

In automatic 
mode the stove 
works at 
maximum 
capacity all the 
time. 
 
 

1.  The  thermostat  is  programmed  to  the  maximum 
position. 
2. The thermostat for outside air always checks the cool 
air. 
3. The probe that checks the temperature is defective. 
4. The control panel is defective or not working. 

1. Set the thermostat temperature again. 
2. Change the probe position.  
3. Check the probe and change if needed. 
4.
 Check the control panel and change if needed. 

The stove does 
not turn on 

1. Check if there is an electricity interruption. 
2. The wooden granules probe is blocked. 
3.  The  pressure  switch  is  not  working  (says  it  is 
blocked). 
4.  The  smoke  vacuum  or  smoke  supply  channel  is 
clogged. 

1. Make sure the plug is in and check if the main 
switch is in I position. 
2. Unblock the probe by checking the thermostat in 
the back. If it blocks again change the thermostat. 
3. Change the pressure switch. 
4. Clean the smoke channel. 

Table 8. 

 

 

  INFORMATION ON DISPOSAL (THROWING AWAY) AND 

DISMANTLING (PULLING APART) THE STOVE 

 
Dismantling and throwing away, or disposing of an old used stove is the sole responsibility of the owner. 
The owner of the stove must abide by the regulations in his/her country related to the safety and environment protection. 

Dismantling and disposing of the stove may be left to a third party to do if the third party is a company authorized to collect 
and dispose of such materials.  

NOTICE: In all cases you must abide by the applicable regulations of the country where the stove is installed regarding 

disposal of such materials (things) and, if necessary, report the disposal of such items. 

ATTENTION  
Dismantling the stove must be done only when the chamber of the stove is not working and when the stove is unplugged 

from power (no power supply).  

• pull out all electric parts,  
• throw away the batteries and electronic cards of the remote control in the proper garbage cans in accordance with the 

standards.  

 separate the batteries you are keeping from the electric cards,  
• dismantle the stove with the help from an authorized company  
ATTENTION  
Disposing  of  the  stove  in  public  places  poses  a  serious  risk  for  people  and  animals.  In  such  cases  it  is  always  the 

responsibility of the owner if a person or an animal gets hurt.  

When the stove is dismantled, this manual and all other documents related to the stove must be destroyed.  
22.0.  THE DURATION OF GUARANTEED SERVICE 
By this we mean the time in which we guarantee service, accessories, and spare parts, starting from the date of purchase 

of the appliances.  

The time of the guaranteed service is in accordance with the legislation.  
In case of a change of the model and design of the appliance, the deadline for replacing the parts for which the design has 

been changed is within the legal deadline.  

After this period the affected parts are provided in the new designs. 
22.1. WARRANTY TERMS AND CONDITIONS 
Product warranty is valid within the legally defined deadline. 
The warranty does not apply to the glass or to the physical damage caused after purchase.
 
THE MANUFACTURER RESERVES ALL RIGHTS TO CHANGES. 
The appliance will, within the warranty period, only function correctly when used in accordance with the instructions for 

connection and use. 

The warranty ceases to be valid if it is determined that:  
- Connecting the product or repair was performed by unauthorized persons, or if they built in counterfeit parts,   
- If the appliance is not properly used in accordance with this instructions manual, 

Содержание DINO 27

Страница 1: ...uel from timber biomass biofuels INSTRUCTIONS FOR CONNECTING OPERATION AND MAINTENANCE OF THE STOVE This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollut...

Страница 2: ...bustion of the pellet in the stove emits the same amount of carbon dioxide CO2 which would be freed as a result of the natural decay of wood The amount of carbon dioxide CO2 obtained through combustio...

Страница 3: ...g h 11 Degree of efficiency at maximum power 93 5 12 Minimum stove power radiation of water included 8 4 kW 13 Radiation stove power at minimum power 1 kW 14 The power of a water heater at minimum pow...

Страница 4: ...NG AND MAINTENANCE for employees who do maintenance 10 SPECIAL MAINTENANCE 10 IMPORTANT SAFETY INFORMATION 10 THE PELLET QUALITY IS VERY IMPORTANT 11 STORING THE PELLET 11 CONNECTING THE HYDRAULIC INS...

Страница 5: ...rd This is because the brunt of the stove is forward During transportation of the stove which has to be completely safe make sure that the forklift has the load that is greater than the weight of the...

Страница 6: ...wood e g beams or other combustible material located near the stove should be protected covered with fireproof material Leave enough clearance for maintenance work If the stove is installed in a kitc...

Страница 7: ...o 15 x 15 cm or a diameter of up to 15 cm and if there is a cover for checking and cleaning If the chimney has a larger cross section than 15x15cm or a diameter greater than 15cm a possible increased...

Страница 8: ...r cleaning the ashes is completely sealed and to seal it after each cleaning Please make sure everything is properly returned to its place and check the condition of the seals Figure 2a Cleaning eleme...

Страница 9: ...id for cleaning plug in SMER DIMA NE DA Figure 7 Mounting the flue pipe Insulation thickness mm Diameter of the smoke exhaust pipe mm D 80 D 100 Diameters of the holes holes to be made mm The walls ar...

Страница 10: ...This hole must be made on the outer wall of the room where the stove is located The supply of combustion air from the garage a warehouse for combustible materials or from a room where there are risks...

Страница 11: ...uld be cold and that the ashes should be cold as well They need to make sure the handles are cold as well NEVER TURN THE STOVE ON if there is just one of the safety devices that is defective improperl...

Страница 12: ...sive cleaners for cleaning the surface of the stove ROUTINE CLEANING AND MAINTENANCE DONE BY THE USER OF THE STOVE Use a drum shaped vacuum cleaner that can facilitate cleaning the stove The vacuum cl...

Страница 13: ...pulling the mechanism button a few times back and forth you will clean the chamber Do not worry if the mechanism moves slowly if it scratches or gets caught This is how it cleans the chamber Clean th...

Страница 14: ...er burning two tons of pellets Make sure the stove and the ash are cool The smoke channel chimney is resistant to wind and has to be checked and cleaned every year best at the beginning of the heating...

Страница 15: ...poor performance of the stove in case of use of the pellets of inappropriate quality STORING THE PELLET The pellets must be kept in a dry place that is not very cold Cold and moist pellets at the temp...

Страница 16: ...e looking at the stove The output safety valves whose connection protrudes through the rear wall above the pressure line should be put into the sewer pipes CIRCULATION PUMP A high quality Wilo RS 25 6...

Страница 17: ...out water It must be tied to the installation to which the consumers are connected radiators with minimum power of 8 kW PRACTICAL INSTRUCTIONS AND TIPS FOR THE USE OF THE HEATING SYSTEM All connection...

Страница 18: ...etting up and use simple and direct user functions reliable and flexible functional software specially developed for pellets burning appliances advanced features available to installers for adapting s...

Страница 19: ...oes into Standby mode LED symbols Igniter LED is on Igniter is on Auger LED is on Auger is active Pump LED is on Pump is active L3 Aux 1 output LED is on Aux 1 output is activated L4 Additional engine...

Страница 20: ...till in the ignition stage The system will stop working only when it enters the Run Mode Link Error This message informs you that there is no communication between the LCD display and the controller o...

Страница 21: ...buffer and other heating parameters Chrono Menu for selecting chrono program mode and boiler on off times Manual Load Menu for manual loading of the auger It is only feasible when the system is in the...

Страница 22: ...alues of the fan speed of the flue gas fans will be increased by 15 compared to the factory values Factory settings U03 1000 U04 1200 U05 1400 U06 1600 U07 1800 U11 900 Calibrated values U03 1150 U04...

Страница 23: ...e stove is set for precisely determined periods of time It contains two submenus Modality Programming Modality By entering the Chrono menu two submenus appear namely Modalities and Programming Via P4...

Страница 24: ...s that can be chosen Daily program the week day is selected and the system on and off times are programmed There are three time ranges for each day Weekly program system on off times are programmed fo...

Страница 25: ...n 3 seconds After that you can find the following functional conditions of the stove Check Up In the check up stage the initial check of the input signals of the stove and the correctness of the probe...

Страница 26: ...set water temperature it goes into modulation and continues to increase the water temperature by inertia up to the value 4 C higher than the set water temperature in the boiler 2 When an external roo...

Страница 27: ...for more than 3 seconds Contact a service Flue gas fan works at speed different than set Er11 Clock error Problems with internal clock Press and hold the P2 button for more than 3 seconds Check the ac...

Страница 28: ...itch on the back side of the stove and on the control panel the motherboard FLUE GASES FAN If the fan stops the motherboard immediately blocks the supply of pellets and an alarm signal will show GEAR...

Страница 29: ...throwing away or disposing of an old used stove is the sole responsibility of the owner The owner of the stove must abide by the regulations in his her country related to the safety and environment p...

Страница 30: ...was due to too much or too low voltage as well as due to force majeure Malfunctions of the appliance can be removed outside the warranty period with original spare parts that we also give a warranty f...