expires, the phase is interrupted and the next phase – the stabilization phase starts. The igniter, the auger and the flue 
gases motor are active during this phase. 

  Stabilization  
The stabilization phase is a transitional state between the ignition phase and the run mode phase. This phase starts 

when the conditions for ignition are met or when flue gases reach the temperature of 45°C. It lasts three minutes and during 
that time the igniter, the auger and the flue gases motor are active. 

  Run Mode  
The boiler run mode phase starts after the stabilization phase. There are five levels of power which can be set during 

this phase (see 10.3.2.1). During this phase, the igniter is inactive while the auger, the flue gases motor and the pump are 
active and operate at different intensity depending on the boiler power level. The boiler is operating at the set power until 
modulation conditions are achieved. 

  Modulation  
The boiler switches to the modulation phase when one of two conditions is achieved: 
1.

 

When the boiler reaches the set water temperature 

2.

 

If the flue gas temperature reaches the value higher than 200°C 

During modulation state, the boiler is operating with minimum power – power 1 until the temperature decreases below 

the limit value. 

  Standby 
The boiler switches to standby mode when one of two conditions is achieved: 
1.

 

When the boiler reaches the set water temperature, it switches to modulation and continues to increase the water 

temperature by inertia to the value of 4°C higher than the set water temperature in the boiler.  

2.

 

When the external (room) thermostat reacts 

During standby mode, the pellet feed stops and the boiler is switched off. The boiler switches on again when the water 

temperature is 4°C lower than the set value or when the room thermostat deactivates. 

    Safety  
The safety mode occurs when the flue gases temperature exceeds 230°C or when the boiler water temperature reaches 

85°C. During this phase, the pellet feed stops until the flue gases temperature is below 230°C or the water temperature in 
the boiler is below 85°C. If there is no temperature reduction in the next 60 seconds, the boiler switches to alarm mode and 
displays a message Er04 or Er05. 

   Extinguishing  
The boiler is turned off by pressing the on/off menu in the screen bottom left corner. The extinguishing phase starts 

during which the pellet feed stops, and the flue gases motor and the pump operate at maximum capacity to cool down the 
boiler as soon as possible. The minimum duration of the extinguishing phase is 300 seconds and the flue gases 
temperature must be below 70°C in order to have the boiler completely extinguished. 

   OFF  
The boiler is turned off in this mode (the flue gases motor, the pump, the igniter and the auger are not active). 
   Block  
The block mode occurs in case of error or alarm. The flue gases fan, the auger and the igniter are switched off during 

the block mode. If the block is resolved or the cause of the alarm is removed, the system will shut down. 

   Recover Ignition  
The boiler switches to this phase in two cases:  

1.

 

If there is a power failure during the operation mode and the flue gases temperature is higher than 45°C. 

2.

 

By pressing the main switch when the boiler is in the extinguishing phase.   

 
 

10.5.

 

Possible problems and solutions  

Display 
message 

Description  

Possible causes 

Resetting errors 

Possible 
alarm 
solutions 

 
 
 
Er01 

 
 
Safety thermostat activation 

 

High boiler water temperature 

Wait until the boiler is 
completely cool and then 
unscrew the plastic cap 
on 
the thermostat and press 
the 
system reset button  

Check the 
validity and 
the 
functionality 
of the pump 

Faulty or badly connected 
pump 

Contact the 
service 

Faulty thermostat 

Er02 

Safety manometer activation 

Flue gases exhaust 
obstruction 

Turn the appliance off 
and then on in the 
ON/OFF menu 

Check if the 
flue pipes 
and the flue 
are dirty 

Boiler thermostat     Auger 
thermostat 

Содержание Grande 37 Lux

Страница 1: ...37 Lux Instruction for use maintenance and installation This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the red...

Страница 2: ...by a person authorized by Alfa Plam The flame that develops in the boiler during normal combustion of wood biomass releases just the amount of carbon dioxide CO2 that would be released by natural wood...

Страница 3: ...CE 10 8 IMPORTANT SAFETY INFORMATION 11 9 PELLET QUALITY IS VERY IMPORTANT 11 9 1 PELLET STORAGE 11 10 BOILER CONTROL SYSTEM 11 10 1 Electrical connection diagram 12 10 2 Touch screen control panel di...

Страница 4: ...ents and or damage occurred due to use of non original or inappropriate spare parts Installations is solely within the responsibility of the installer 2 1 MAIN USER RESPONSIBILITIES The boiler user mu...

Страница 5: ...ommissioning inspect the operation during at least 30 minutes in order to check whether all requirements have been met After finishing the installation the installer should provide the customer with t...

Страница 6: ...the 80 mm flue pipe Therefore make sure that the flue pipe is completely sealed Carefully analyze the position and condition of the space through which the flue passes If the flue pipe passes through...

Страница 7: ...ent always turned upward Figure 4 We recommend not making long horizontal sections for the flue connection If there is no other possibility the flue pipes should not have a downward slope but upward t...

Страница 8: ...7 AISI 316 steel flue with double insulated chamber material resistant to 400 C Optimal efficiency 100 Waterproof flue with double insulated chamber and outer casing of light concrete Optimal efficien...

Страница 9: ...ng devices such as a hoods hair dryers fans etc located in the room with the boiler combustion air fresh air must be supplied from outside In any case this should be discussed with the competent chimn...

Страница 10: ...e universal ones Check if the valve is easily opened check with a finger so that it could be opened with the pump s power The non return valve is placed behind each pump If there are multiple pumps yo...

Страница 11: ...nting damage due to sudden failure of a component which may seriously endanger the safety of persons and or your property Clean the firebox and the space underneath it when cleaning the ashes 6 2 SAFE...

Страница 12: ...to the following safety rules Turn the pellet boiler off before beginning any procedure Make sure that the ash is cold before beginning any procedure on the boiler Vacuum the ashes deposited in the c...

Страница 13: ...ONS ENSURE THE MAXIMUM OUTPUT OF THE BOILER AND THE TEMPERATURE OF THE SYSTEM Make sure that the pellet boiler and ashes are cold For complete weekly cleaning or after 200 kg of used pellets whichever...

Страница 14: ...he type and quality of the pellets The manufacturer is not in any way responsible for poor performance of the boiler due to the use of poor quality pellets If sawdust or small decomposed pellets are p...

Страница 15: ...isplay 1 2 Start screen display 2 2 YELLOW GREEN POWER CABLE FLUE GAS FAN TURBULATOR REDUCER PRIMARY AIR FAN LIGTER AUGER REDUCER THERMOMETER MANOMETER PENDULUM REDUCER PUMP MICRO SWITCH 1 MICRO SWITC...

Страница 16: ...Auger Auger on off Pump Pump on off Valve Pendulum reducer on off V2 Room fan on off V3 Turbulator reducer on off A1 Heater igniter on off A3 Pendulum reducer on off A5 Auger reducer blocked not bloc...

Страница 17: ...ition failure Er15 Power outage longer than 50 minutes Er16 Communication error RS485 Er17 Airflow regulator error Er18 No pellet Er25 Firebox cleaning motor error Er26 Turbulator cleaning motor error...

Страница 18: ...es Boiler Thermostat The adjustable boiler water temperature range is from 40 C to 80 C By setting the temperature of the water in the boiler the user sets the operating condition of the boiler i e th...

Страница 19: ...the steps decreases and increases the calibrated auger speed Fan Calibration menu for changing the speed of the flue gas fan The system has 15 calibration steps from 7 to 7 the factory setting is 0 Th...

Страница 20: ...s is performed during the check up phase During this phase the flue gases motor is working at maximum speed while the auger and the igniter are turned off The check up phase takes a few seconds and th...

Страница 21: ...ases temperature exceeds 230 C or when the boiler water temperature reaches 85 C During this phase the pellet feed stops until the flue gases temperature is below 230 C or the water temperature in the...

Страница 22: ...ck error Internal clock problems Turn the appliance off and then on in the ON OFF menu Check the accuracy of the set time Insufficient internal battery capacity Check the accuracy of the chrono mode p...

Страница 23: ...t and cleanliness Contact the service NOTE If the recommended solution fails to remove the direct cause of the alarm CONTACT ALFA PLAM CALL CENTER or the closest authorized service 11 INFORMATION ON B...

Страница 24: ...8 Flue gas temperature value at reduced power C 70 Mean NOx value at 10 O2 at rated power mg m3 191 Mean CO value at 10 O2 at rated power mg m3 26 Mean dust emission value at 10 O2 at rated power mg m...

Страница 25: ...d floor heating Note If only floor heating is connected to the boiler make sure to install an accumulation tank BUFFER Legend 1 Pellet boiler 2 Air vent 3 Safety valve 3 bar 4 Three way mixing valve w...

Страница 26: ...draulic installation diagram accumulation tank Legend 1 Pellet boiler 2 Air vent 3 Safety valve 3 bar 4 Air vent 5 Circulation pump 6 Three way mixing valve with pipe thermostat 7 Accumulation tank BU...

Отзывы: