4 Installation
SaniMidget/SaniMagnum/SaniMega SB
4.5
Installation
The Alfa Laval Toftejorg SaniMxxxx SB clip-on versions are installed on:
1” BPE US down pipe (16B102-xx or 16B132-xx)
1½” BPE US down pipe (16B152-xx or 16B182-xx or 17Bxxx-xx)
2” BPE US down pipe (18Bxxx-xx)
The Alfa Laval Toftejorg SaniMxxxx SB weld-on versions are installed on:
1” BPE US down pipe (16B203-xx or 16B233-xx)
1”ISO down pipe (16B202-xx or 16B232-xx)
DIN Range 1 Ø28 down pipe (16B102-xx or 16B132-xx)
1½” BPE US down pipe (17B203-x0 or 17B233-x0)
2” BPE US down pipe (18B203-x0, or 18B233-x0, or 18B263-x0, or 18B293-x0)
Correct down-pipe dimensions are important to ensure volumetric flow rates as provided in this manual. Clip-on hole centre for
1” must be less than 15 mm (0.59”) from the bottom end (recommended 13-15 mm – 0.51”-0.59”) of the down-pipe and for the
1½” and 2” less than 34 mm (1.33”) from the bottom end (recommended 30-34 mm – 1.18”-1.33”). For weld-on versions no
clip hole is needed – the connector (containing the clip hole) is welded on the end of the down pipe.
Important
information:
Alfa Laval Toftejorg SaniMxxxx SB weld-on versions:
To continue to meet the requirements of the 3-A Sanitary Standard 78-##, the weld-on version shall be
welded onto the end of a straight down pipe. This straight down pipe shall be connected to the supply
system in a dismountable manner. This shall allow for easy disassembly and reassembly (e.g. a sanitary
clamp coupling) to allow visual inspection (through the down pipe) of the inside of the down pipe and the
inside of the connector. Welding must be performed in accordance with 3-A accepted Standard 605-##..
19