8.2
Connection list
Alfa Laval ref. 557533 rev. 2
Connection No.
Description
Requirements/limit
201
Inlet for process liquid
- Permitted temperatures
M100 °C
minimum 0 °C
206
Inlet for liquid seal and displacement liquid
- Quality requirements
Fresh water
- Instantaneous flow
5,5 litres/minute
- Pressure
150-600 kPa
220
Outlet for light phase (oil)
- Counterpressure
Maximum 360 kPa
221
Outlet for heavy phase (water)
No counterpressure
222
Outlet for solid phase
The outlet after the
separator should be
installed in such a way
that you can not fill the
frame top part with
sludge. (Guidance of
sludge pump or open
outlet)
372
Inlet for discharge liquid
- Instantaneous flow
18 litres/minute
- Quality requirements
See ‘‘8.4 Water quality”
on page 146
- Pressure
150-600 kPa
- Time
1 second per discharge
www.fdm.com.pe
Содержание MMPX 303SGP-11
Страница 6: ...ventas fdm com pe fdmsac gmail com Movil 959440045 6 www fdm com pe...
Страница 14: ...ventas fdm com pe fdmsac gmail com Movil 959440045 2 Safety Instructions 14 www fdm com pe...
Страница 78: ...ventas fdm com pe fdmsac gmail com Movil 959440045 78 www fdm com pe...
Страница 124: ...ventas fdm com pe fdmsac gmail com Movil 959440045 124 www fdm com pe...
Страница 155: ...ventas fdm com pe fdmsac gmail com Movil 959440045 155 www fdm com pe...
Страница 159: ...ventas fdm com pe fdmsac gmail com Movil 959440045 159 www fdm com pe...
Страница 174: ...ventas fdm com pe fdmsac gmail com Movil 959440045 174 www fdm com pe...
Страница 176: ...ventas fdm com pe fdmsac gmail com Movil 959440045 176 www fdm com pe...
Страница 178: ...ventas fdm com pe fdmsac gmail com Movil 959440045 178 www fdm com pe...