2 Safety
All warnings in the manual are summarised on this page.
Pay special attention to the instructions below so that severe personal injury and/or damage to the pump are avoided.
2.3
Safety precautions
Installation:
Always read the technical data thoroughly. (See chapter 6 Technical data)
!
Always use a lifting crane when handling the pump.
Pump without impeller screw:
Always remove the impeller before checking the direction of rotation.
Never start the pump if the impeller is fitted and the pump casing is removed.
Pump with Impeller screw:
Never start in the wrong direction of rotation with liquid in the pump.
Always have the pump electrically connected by authorised personnel. (See the motor instruction)
Operation:
Always read the technical data thoroughly. (See chapter 6 Technical data)
!
Never touch the pump or the pipelines when pumping hot liquids or when sterilising.
Never run the pump with both the suction side and the pressure side blocked.
Never run the pump when partially installed or not completely assembled.
Necessary precautions must be taken if leakage occurs as this can lead to hazardous situations.
Always handle lye and acid with great care.
Never use the pump for products not mentioned in the Alfa Laval pump selection program.
The Alfa Laval pump selection program can be acquired from your local Alfa Laval sales company.
Maintenance:
Always read the technical data thoroughly. (See chapter 6 Technical data)
!
Never service the pump when it is hot.
Never service the pump if pressurised.
Always use Alfa Laval genuine spare parts.
Motors with grease nipples:
Remember lubrication according to information plate/label on the motor.
Always disconnect the power supply when servicing the pump.
Transportation:
Transportation of the pump or the pump unit:
Never lift or elevate in any way other than described in this manual
Always drain the pump head and accessories of any liquid
Always ensure that no leakage of lubricants can occur
Always transport the pump in its upright position
Always ensure that the unit is securely fixed during transportation
Always use the original packaging or similar during transportation