Alfa Laval AlfaBlue Junior AG 351 Скачать руководство пользователя страница 1

ORIGINAL INSTRUCTIONS

AHE00060EN 1904

Alfa Laval AlfaBlue Junior AG/XG

Instruction manual

•  Product description

•  Product labels

•  Unpacking & lifting

•  Installation

•  Maintenance

•  Spare parts

Содержание AlfaBlue Junior AG 351

Страница 1: ...ORIGINAL INSTRUCTIONS AHE00060EN 1904 Alfa Laval AlfaBlue Junior AG XG Instruction manual Product description Product labels Unpacking lifting Installation Maintenance Spare parts...

Страница 2: ...Options 4 2 4 Code description 5 3 Product labels 5 4 Unpacking and lifting 4 1 Packing 8 4 2 Shipping dimensions 8 4 3 Feet mounting for vertical airflow 9 4 4 Lifting from above 10 5 Installation 5...

Страница 3: ...ut into operation until the conformity of the complete machine or cooling system has been declared according to the following standards and directives Pressure Equipment Directive 2014 68 EU Machine D...

Страница 4: ...1 mm Each heat exchanger is leak tested with dry air nitrogen for XG and finally supplied with a nitrogen pre charge Model Design pressure Test pressure AlfaBlue Junior AG H 33 45 bar 47 65 bar AlfaB...

Страница 5: ...C 8 No of phases S 1 D 3 9 Units are suitable for both horizontal and vertical airflow mounting feet kit required for vertical airflow setup 10 Packing BO box CR crate 11 Options 12 Fin material AL a...

Страница 6: ...r tube Fluid Group According to PED Coil Ts Range of operating tem peratures for the coil Ps Design pressure Pt Test pressure Test date Date on which the coil has been pressure tested in the factory W...

Страница 7: ...SCHALTUNG AUF AUTOMATIK INTERNE BAUTEILE IN BETRIEB VOR ARBEITSBEGINN SPANNUNG UNTERBRECHEN L MENTS INTERNES A D MARRAGE AUTOMATIQUE COUPER L ALIMENTATION LECTRIQUE AVANT INTERVENTION Cod 69100175 7 8...

Страница 8: ...g Including fan speed control switchboard Length cm Width cm Height cm Volume m3 Weight kg Length cm Width cm Height cm Volume m3 Weight kg 351 box 95 53 72 0 4 30 95 53 70 0 4 32 352 box 155 53 72 0...

Страница 9: ...nto supports Use supports for each mounting foot position The supports must span the full casing width to avoid damage to the finned coil Loosen fixing bolts and remove all mounting profiles For AG XG...

Страница 10: ...ax 30 max side view AlfaBlue Junior heat exchangers can be lifted from above For models with 2 or more fans the use of a hoisting beam is required AG XG63 models are supplied with lifting lugs For oth...

Страница 11: ...as given in the air cooled con densers gas coolers product manual AHE00049 5 1 Mounting dimensions Drawings showing all required mounting and refrigerant connection dimensions are available for downlo...

Страница 12: ...Corporate AB Alfa Laval reserves the right to change specification without prior notification Mounting dimensions model 351 352 353 Vertical airflow 294 600 10 555 548 35 28 12 TOP VIEW Side view all...

Страница 13: ...e AB Alfa Laval reserves the right to change specification without prior notification Mounting dimensions model 50 Horizontal airflow 2660 2700 5 2965 10 860 900 5 1165 10 1760 1800 5 2065 10 3865 10...

Страница 14: ...AB Alfa Laval reserves the right to change specification without prior notification Mounting dimensions model 50 Vertical airflow 45 60 16 TOP VIEW Side view all models Mounting profile 890 10 420 85...

Страница 15: ...t to change specification without prior notification 5265 10 2000 1000 1960 5000 10 6265 10 2000 2000 1960 6000 10 1960 2000 4000 10 4265 10 3265 10 2960 3000 5 1960 2000 5 2265 10 960 1000 5 1265 10...

Страница 16: ...to change specification without prior notification 6265 10 2000 2000 1960 6020 10 5265 10 2000 1000 5020 10 1960 2000 1960 4020 10 4265 10 2960 3020 5 3265 10 1960 2020 5 2265 10 1265 10 960 1020 5 1...

Страница 17: ...ration dampers 45 mm 60 mm min 145 mm min 160 mm min 100 mm Vertical airflow min 140 mm min 100 mm Horizontal airflow model 35 min 490 mm model 50 min 570 mm model 63 min 850 mm For active and passive...

Страница 18: ...e vibrations in the piping Picture shows an installation example using threaded bar nut grower washer washer and locknut not supplied This way vibration dampers can be used to make the cooler level ad...

Страница 19: ...ect switchboard position horizontal airflow Correct switchboard position vertical airflow Default switchboard position at delivery Incorrect switchboard position horizontal airflow 5 7 Installation la...

Страница 20: ...otor type Electrical options Electrical connection diagrams are available for download on www alfalaval com When in doubt always contact your local Alfa Laval representative for assistance Electrical...

Страница 21: ...fan power supply Start the fans and verify fan direction After some operating time verify that current absorbtion does not exceed the value as given in the technical specifications 6 2 Shutdown If th...

Страница 22: ...ructions as given in air cooled condensers gas coolers product manual AHE00049 7 1 Fan replacement Disconnect fan cabling Unscrew fixing bolts and remove old fan Mount new fan assembly in identical po...

Страница 23: ...a Laval Anytime Spare parts for AlfaBlue Junior End cover bend side End cover connection side Mounting profiles horizontal airflow Mounting feet vertical airflow Fan Vibration damper Switch on off Spa...

Страница 24: ...www alfalaval com...

Отзывы: