1

Petrol Driven 2"  

Diesel & Water Transfer Engine Pump

OWNER’S TECHNICAL MANUAL

P50

Uses

Diesel and water transfer

Engine Type

OHV 4 stroke, Air Cooled

Maximum Flow Rate

600 L/min

IMPORTANT

Please make certain that persons who are to use this equipment thoroughly read and understand these instructions  
and any additional instructions provided prior to operation.  

NOTE
No refund or exchange once petrol is placed into the fuel tank. Warranty registration must be complete within 30 days of purchase 
with proof of purchase.

Description

The Alemlube P50 petrol driven 2" transfer engine pump is specifically designed and manufactured for the transfer of diesel 

and water. Mounted in a robust tubular steel roll frame with rubber feet the P50 is completely portable, suits many industrial, 

workshop,agricultural, municipal, marine services and on site applications including construction site dewatering and is capable of 

transferring up to 600 litres of diesel fuel or water per minute.
Driven by a powerful OHV 4 stroke air cooled petrol engine this lightweight die-cast aluminium pump with 2" diameter inlet & outlet 

ports operates efficiently with a maximum suction head of 8 metres and a maximum lift head of 28 metres.
Always ready to perform tank filling, diesel or water transfer the P50 has a 3.6L fuel tank capacity with a manual starting system.

Specifications

March 2021

Содержание P50

Страница 1: ...arranty registration must be complete within 30 days of purchase with proof of purchase Description The Alemlube P50 petrol driven 2 transfer engine pump is specifically designed and manufactured for the transfer of diesel and water Mounted in a robust tubular steel roll frame with rubber feet the P50 is completely portable suits many industrial workshop agricultural municipal marine services and ...

Страница 2: ...2095 SA NT TEL 08 8241 7111 FAX 08 8241 7011 NZ TEL 09 447 1007 FAX 09 447 1008 2 Petrol Driven 2 Diesel Water Transfer Engine Pump OWNER S TECHNICAL MANUAL P50 1 INSTALLATION AND OPERATION 3 1 1 INSTALLATION 3 1 2 SAFE OPERATION 3 2 BEFORE STARTING 4 3 STARTING THE ENGINE 5 4 STOPPING THE ENGINE 6 5 TROUBLE SHOOTING 7 6 MAINTENANCE 8 9 7 PROHIBITED OPERATION MESSAGE 10 8 STORAGE AND TRANSPORTATIO...

Страница 3: ... OWNER S TECHNICAL MANUAL P50 1 Installation Install the pump on an even surface in a well ventilated place Do not install more than 7m above stored diesel or water supply Install a filter in the inlet pipe 1 1 Safe Operation Do not operate in a confined or badly ventilated place or near to flammable liquids Filling fuel stop engine Filling fuel do not smoke Filling fuel do not splash fuel CAUTION...

Страница 4: ...3 8787 8266 WA TEL 08 9302 4199 FAX 08 9303 2095 SA NT TEL 08 8241 7111 FAX 08 8241 7011 NZ TEL 09 447 1007 FAX 09 447 1008 4 Petrol Driven 2 Diesel Water Transfer Engine Pump OWNER S TECHNICAL MANUAL P50 1 CONNECT THE HOSE 1 Insert 2 Tighten 3 Insert 4 Tighten 5 Screw in 4 2 FILL PRIMING DIESEL OR WATER 1 Remove cap 2 Fill with diesel or water 3 Replace cap BEFORE STARTING 2 ...

Страница 5: ...166 FAX 07 3204 1224 VIC TAS TEL 03 8787 8288 FAX 03 8787 8266 WA TEL 08 9302 4199 FAX 08 9303 2095 SA NT TEL 08 8241 7111 FAX 08 8241 7011 NZ TEL 09 447 1007 FAX 09 447 1008 5 Petrol Driven 2 Diesel Water Transfer Engine Pump OWNER S TECHNICAL MANUAL P50 1 ON 2 OPEN 1 ON 3 CLOSE 4 ON 5 FULL 6 OPEN 7 FULL STARTING THE ENGINE 3 ...

Страница 6: ... TEL 07 3204 9166 FAX 07 3204 1224 VIC TAS TEL 03 8787 8288 FAX 03 8787 8266 WA TEL 08 9302 4199 FAX 08 9303 2095 SA NT TEL 08 8241 7111 FAX 08 8241 7011 NZ TEL 09 447 1007 FAX 09 447 1008 6 Petrol Driven 2 Diesel Water Transfer Engine Pump OWNER S TECHNICAL MANUAL P50 1 POSITION 2 OFF 3 OFF STOPPING THE ENGINE 4 ...

Страница 7: ...AX 08 9303 2095 SA NT TEL 08 8241 7111 FAX 08 8241 7011 NZ TEL 09 447 1007 FAX 09 447 1008 7 Petrol Driven 2 Diesel Water Transfer Engine Pump OWNER S TECHNICAL MANUAL P50 ENGINE WILL NOT START 1 CHECK FUEL 2 CHECK SPARK 1 Remove check spark plug WILL NOT PUMP 1 Check priming 2 Check strainer for clogging 3 Check that the suction pipe is airtight 1 Check hose clamps 2 Check hose for damage TROUBLE...

Страница 8: ... 7111 FAX 08 8241 7011 NZ TEL 09 447 1007 FAX 09 447 1008 8 Petrol Driven 2 Diesel Water Transfer Engine Pump OWNER S TECHNICAL MANUAL P50 CHECK OIL BEFORE STARTING SAE 10W 30 OR EQUIVALENT MOTOR OIL SAE 10W 30 CHANGE THE OIL AFTER THE FIRST MONTH OR AFTER 20 HOURS WHICH EVER COMES FIRST AFTER THIS EVERY 6 MONTHS OR 100 HOURS WHICH EVER COMES FIRST DRAIN FILL 0 6L SPARK PLUG ENGINE TROUBLE REMOVE ...

Страница 9: ... 8787 8288 FAX 03 8787 8266 WA TEL 08 9302 4199 FAX 08 9303 2095 SA NT TEL 08 8241 7111 FAX 08 8241 7011 NZ TEL 09 447 1007 FAX 09 447 1008 9 Petrol Driven 2 Diesel Water Transfer Engine Pump OWNER S TECHNICAL MANUAL P50 MAINTENANCE 13 AIR CLEANER TROUBLE WASH DRY KEROSENE SOAK SQUEEZE ENGINE OIL SPARK PLUG ENGINE TROUBLE REMOVE PLUG CLEAN ADJUST GAP 0 7 0 8mm ...

Страница 10: ...R S TECHNICAL MANUAL P50 7 1 Before adding oil stop operating the engine 7 2 Suitable only for the transfer of clean diesel fuel or clean water 7 3 Do not transfer contaminated fluid 7 4 Not to be used for draining mud 7 5 Atmospheric temperature can t be less than 0 or more than 40ºC 7 6 Engine should be stopped immediately when the temperature is beyond this temperature range 7 7 Warranty does n...

Страница 11: ...3 Mechanical Seal P50 04 Impeller P50 05 Volute Casing P50 06 Volute Casing Gasket P50 07 Pump Hosing Part Number Description P50 08 Discharge Flange P50 09 Pip Connector P50 10 Nut Connector P50 11 Discharge Flange P50 12 Priming Plug P50 13 ORing Plug P50 14 Bolt M8 20 Part Number Description P50 15 Inlet Valve Gasket P50 16 Inlet Flange P50 17 Bolt M8 20 P50 18 Bolt M8 25 P50 19 Gasket P50 20 N...

Отзывы: