Flow rate:
Up to 60L/min
Operating pressure (Max): 50psi (3.5bar)
Operating temperature:
-10ºC ~ 60ºC
Accuracy:
±
1%
Fluid type:
Diesel, petrol & kerosene
Digital Screen:
5-Digit present total (0.01
~
999.99)
7-Digit non-resettable total (1
~
9999999)
Units - Litres, gallons, pints, quarts
Inlet and Outlet:
1" BSP swivel inlet & 19mm (3/4") outlet spout
Weight:
1.3kg
Power supply:
2 x AAA
INTRODUCTION:
1.1
Technical Data
1.1.1 The liquids compatible with auto shut off digital nozzle must be low viscosity.
1.2
LCD Display
The “LCD” of the meter features two numerical Registers and various indications
displayed to the user only when the applicable function so requires
KEY
1. Partial register (5 figures with moving comma from 0.1 to 99999)
Indicating the volume dispensed since the reset button was last pressed
2. Indication of battery charge
3. Indication of calibration mode
4.
Indication of resetting present total to Zero
5.
Total register
6.
Indication of flow rate mode
7.
Indication of unit of measurement of partial: L= Litres
Description
The 51037M auto shut off nozzle uniquely designed with a built in digital meter is suitable for dispensing diesel fuel,
petrol, kerosene and will automatically shut off when a tank is full. This innovative combination of nozzle and meter saves
simplifies traditional separate nozzle and meter thinking and saves installation and usage time.
The digital meter is powered by 2 x AAA batteries, displays a 5-digit resettable total and a 7-digit (non resettable)
cumulative total function, and is accurate to ±1%. The LCD display can indicate several modes by pressing the menu
button including level of battery charge, flow rate, calibration and units of dispensed fuel (litres, gallons, pints or quarts).
And for peace of mind, spare parts for both nozzle and meter are readily available.
Flow rates of up to 60 L/min are achievable within operating temperatures of -10ºC to 60ºC with an operating pressure of
7 to 50psi (0.5-3.5 bar).
The 51037M comes complete with a 1” BSP(f) swivel and the outlet spout is 19mm (3/4”) in diameter.
Visit our website at
www.alemlube.com.au
Email - [email protected]
NSW
TEL: (02) 9939 0711
FAX: (02) 9939 0411
QLD/PNG
TEL: (07) 3204 9166
FAX: (07) 3204 1224
VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266
WA
TEL: (08) 9302 4199
FAX: (08) 9303 2095
SA/NT
TEL: (08) 8241 7111
FAX: (08) 8241 7011
NZ
TEL: (09) 447 1007
FAX: (09) 447 1008
51037M
Auto Shut Off Nozzle with Digital Meter
51037M
OWNER’S TECHNICAL MANUAL
Specifications
� �ndication of resetting present total to �ero
� Total register
� �ndication of flow rate mode
� �ndication of unit of measurement of partial: L= Litres
GAL = Gallons
PT = Pints
QT = Quarts
1.3 USER BUTTONS
The turbine digital meter features two buttons (MENU and RESET) which individually perform two main
functions and together, other secondary functions.
The main functions performed are:
For the reset key, resetting the partial Register and reset table total (reset total)
For the menu key, entering instrument calibration mode.
Used together, the two keys permit entering configuration mode
1.4 BATTERY REPLACEMENT
When replacing the battery, please open the cover, remove the plug and replace the battery.
2. INSTALLATION
This nozzle is designed to dispensing diesel fuel under 0.5~3.5bar/7~50psi pressure system.
2.1 Connect the nozzle directly with the delivery hose. Please be ensured the thread is sealed.
2.2 Turn on the dispenser, open the trigger of nozzle to start dispensing. For first time using, it is
necessary to turn the trigger on and off 2-3 times to discharge the air inside.
2.3 After dispensing, turn off the nozzle and take back to nozzle holder.
Fig. 1