Alemlube 5005AN Скачать руководство пользователя страница 1

Description

The 5005AN refueling drum pump is designed for the transfer of fuels and lubricants up to SAE30. This economical and

hard working drum pump has a delivery rate of approximately 1 litre per stroke or approximately 40 litres per minute.

Lightweight, the pump is supplied with 2.4 metres of delivery hose, a versatile metal delivery spout and a spout holster.

The simple and proven design of the 5005AN makes this pump the ideal drum pump for fuel and lubricant transfer in

challenging and harsh operating environments.

Specifications

Use

Petrol, diesel, kerosene and lubricants up to SAE30 from 60 or 205 litre drums

Discharge Volume

40 litres per minute or 1 litre per stroke

Inlet/Outlet

Inlet: 1”BSP Outlet: 1”BSP

Hose

2.4 metres of 1”ID fuel resistant hose

Materials

Aluminium handle, aluminium body with POM piston and piston rings

Fitting the telescopic downtube to the pump

Screw the downtube to the pump, carefully applying the thread tape to the

thread on the downtube to ensure there are no air leaks between the

downtube and the pump inlet whilst securing the downtube firmly in place.

Fitting the pump to the drum or tank

1

Pull out the short tube to the fully extended position then place the pump

in the drum or tank.

2

Screw the pump to the drum or tank firmly.

Fitting the hose to the pump (Sequence Is Important)

1

Place the hose & spout in the hose holster. (The locking pin on the spout

engages in the keyway at the extreme left of the holsters opening).

2

Turn the spout fully clockwise to ensure that when fully assembled, the

nozzle locking pin rests vertically within the holster.

3

Fit the hose clamp loosely to the end of the hose and slide the spring

down onto the hose.

4

Push the hose end onto the pump outlet, slide the hose clamp over the

hose at the outlet and tighten. Slide the hose spring up against the hose

clamp. Check that the spout locking pin is still in a vertical position inside

the holster. If not, adjust the hose position on the spout to correct this.

Pump Operation

When the handle is pulled back, the piston is pushed up by the con rod and

the valve closes. At the same time fuel or lubricant on the top of the piston is

discharged through the hose. When the handle is pushed forward, the piston

is pulled down by the cross bar and the valve is opened. The fuel or lubricant

then flows past the valve through the centre of the piston and fills the cylinder

above the piston. The inlet valve is closed during this stroke.

SERVICE INSTRUCTIONS

Refuelling Drum Pump

5005AN

Visit our website at

www.alemlube.com.au

Email - [email protected]

NSW

TEL: (02) 9939 0711
FAX: (02) 9939 0411

VIC/TAS

TEL: (03) 8787 8288
FAX: (03) 8787 8266

QLD

TEL: (07) 3889 8480
FAX: (07) 3889 8490

SA/NT

TEL: (08) 8241 7111
FAX: (08) 8241 7011

WA

TEL: (08) 9209 3066
FAX: (08) 9209 3933

Отзывы: