background image

      

Service Guide

3690-C
3691-C
3693-C
3696-C

Alemite Corporation

167 Roweland Drive, Johnson City, Tennessee 37601

www.alemite.com

Copyright 

© 

2004 by Alemite Corporation

This document contains confidential information that is the property of Alemite Corporation

670868

and is not to be copied, used, or disclosed to others without express written permission.

Revision (10-04)

SER 3690-C

Figure 1

Preset Metered Control Valve

Preset Metered Control Valve

Valve Model

Inlet

Register Units

Acurracy

Maximum Pressure

Current (w/ Range)

Totalizer

psi

Bar

3690-C

1/2

 

" NPTF (f)

Quart (0-60)

Gallon

+ / - 0.65 %

1000

69

3691-C

Gallon (0-15)

Gallon

3693-C

Liter (0-60)

Liter

3696-C

Quart (0-16)

Quart

Table 1   Preset Metered Control Valve Models 3690-C, 3691-C, 3693-C, and 3696-C

Description

These preset metered valves are designed to 

dispense preset quantities of fluid lubricants. 
Each model is equipped with an inlet swivel, a 
high-volume manual nozzle, and rigid extension.

The models differ in the units of measure that 

are metered and the face dial range. See Table 1 
for details. 

A totalizer keeps a lifetime record of the 

amount dispensed in a unit of measure labeled on 
the dial.

These models are also equipped with an 

internal filter screen to prevent damaging 
contaminants from entering the meter.

Operation

Turn the pointer counterclockwise to the 

required quantity of fluid to be dispensed. To 
dispense, depress the lever until it locks.

The lever disengages automatically once the 

preset amount is delivered.

Emergency Release Mechanism

To stop a preset delivery before completion, 

move the lock pawl to the right. See Figure 1.  
This releases the lever and stops delivery.

CAUTION

Do not turn the pointer clockwise. Damage can occur.

1-800-548-1191-http://[email protected]

Содержание 3690-C

Страница 1: ...alves are designed to dispense preset quantities of fluid lubricants Each model is equipped with an inlet swivel a high volume manual nozzle and rigid extension The models differ in the units of measure that are metered and the face dial range See Table 1 for details A totalizer keeps a lifetime record of the amount dispensed in a unit of measure labeled on the dial These models are also equipped ...

Страница 2: ... 3690 C Preset Metered Control Valve Revision 10 04 2 Alemite Corporation Figure 2 Preset Metered Control Valve Models 3690 C 3691 C 3693 C and 3696 C 1 800 548 1191 http www partdeal com info partdeal com ...

Страница 3: ...7 60 4 393307 160 Register Assembly 1 3693 C 3696 C 393307 62 3 21 393307 164 Screw 4 393307 108 13 22 Washer 1 393307 125 28 23 Gear Pointer 1 3690 C 3691 C 3693 C 393307 126 31 Gear Pointer 1 3696 C 393307 128 9 24 393307 156 Pointer w Setscrew 1 393307 129 26 25 393307 163 Shroud 1 393307 130 10 26 Screw 4 393307 132 38 27 393307 11 Dial Quart w Gallon Totalizer 1 3690 C 393307 133 11 Dial Gall...

Страница 4: ...ith the setscrew See Figure 2 5 Loosen the setscrew that secures the Pointer to Spindle and Gear Assembly 7 6 Remove Dial 27 Cam 17 and Pointer 24 as an assembly from the Spindle and Gear Assembly 7 Carefully pry the Pointer from the Cam Assembly and Dial to separate components 8 Remove Springs 18 and Rollers 19 from the Cam 9 Remove Retaining Ring 15 that secures Lock Pawl 14 to the Housing Remov...

Страница 5: ... Lock Pawl to the post Clean and Inspect 1 Clean all metal parts in cleaning solvent The solvent should be environmentally safe 2 Inspect all parts for wear and or damage Replace as necessary 3 Closely inspect the mating surfaces of all components for any imperfections Ensure a smooth and clean contact is obtained when assembled Assembly NOTE Prior to assembly certain compo nents require lubricati...

Страница 6: ...s 18 into the Cam 24 Install and seat Pointer 24 onto the Cam IMPORTANT Make sure the three holes on the Dial engage with the Register s posts 25 Install and seat the Pointer Cam and Dial assembly onto the shaft of the Spindle and Gear Assembly Make sure the Lock Pawl fits properly into the hole of the Dial NOTE The Pointer s setscrew must point toward the flat on the Spindle and Gear Assembly 26 ...

Страница 7: ...ial 2 Replace Valve Assembly 28 Leakage at Swivel Assembly 35 1 Initial tightening of Swivel Assembly 35 not sufficient 2 Seal worn or damaged 1 Tighten Swivel Assembly 35 2 Replace Swivel Assembly 35 Leakage at Cam 37 Quad Rings 36 worn or damaged Replace Quad Rings 36 Leakage at front end of Nozzle Nozzle damaged Replace Nozzle Leakage at Extension Assembly 1 Initial tightening not sufficient 2 ...

Страница 8: ...SER 3690 C Preset Metered Control Valve Revision 10 04 8 Alemite Corporation 1 800 548 1191 http www partdeal com info partdeal com ...

Отзывы: