background image

Sliding Gate Operator 

User’s Manual 

 Model: AC1400 

Содержание AC1400

Страница 1: ...Sliding Gate Operator User s Manual Model AC1400...

Страница 2: ...portant safety precautions 2 2 Main features 2 3 Main technical parameters 2 4 Necessary Tools 3 5 Site Preparation 3 6 Mechanical Installation 4 7 Electrical 7 8 Tuning and operation 10 9 Check 14 10...

Страница 3: ...l the gate operator on the inside of the property DO NOT install it on the outside of the property where the public has access to it z Be careful when in close proximity to moving parts where hands or...

Страница 4: ...e if you have not already done so wire a waterproof outlet near the gate following proper safety standards for your area If you are not experienced with this type of wiring or if your area requires it...

Страница 5: ...he concrete pad should be approximately 24 600mm x 12 300mm x 18 460mm deep in order to provide for adequate operation Once the gate is mounted adequately electrical power is available and the concret...

Страница 6: ...the clutch Remove the elastic band from the shaft and line up the key on the shaft with the sprocket at the chain box Insert the sprocket from the chain box into the operator shaft Place the operator...

Страница 7: ...6 Gate Round frame Fig 5 Chain Close the gate and attach a chain bolt to the piece of chain that comes with the chain box using enclosure master links Tighten the chain bolt to the bracket with washe...

Страница 8: ...ne is higher and another is lower Verify and if necessary exchange the two brackets position Also if necessary exchange the limit switch wires CL close and OP open Another common problem is there are...

Страница 9: ...AC1400 SLIDING GATE OPERATOR Control board scheme Fig 7 8...

Страница 10: ...power supply CL COM OP N C For N C limit switch CL COM OP N O For N O limit switch Limit switch mode is adjustable by DIP switch See table 3 Schematic diagram Control board Motor wiring terminal E W V...

Страница 11: ...X8 No 15 Terminal X8 No 15 Loop detector with AC input Infrared with AC input Schematic diagram 16 Beeper DC12V 17 Learn button AN 18 Dip switch 19 Antenna ANT 8 Tuning and operation Remote control B...

Страница 12: ...nction and auto close function of pedestrian mode are shut off ON Limit switch mode is NC 3 OFF Limit switch mode is NO z Set auto close function This feature can be selected to make the gate stay ope...

Страница 13: ...utomatically at its closed position if the magnetic limit switch is reached After this setup is complete return DIP switch 1 to OFF position immediately Thus the auto close function of pedestrian mode...

Страница 14: ...n Factory preset OFF position both auto close function and auto close function of pedestrian mode were shut off z Safe guard Infrared device If the infrared beam is broken during closing the gate will...

Страница 15: ...loop detector detects vehicles when the gate stops the gate will open immediately After vehicles move out of the loop the gate will stop and then close after 10 seconds z Limit switch The switch is u...

Страница 16: ...open or close Power switch is OFF Make sure power switch is ON The indicator light of remote control does not light Check the batteries on your remote control Remote control is not suitable for recei...

Отзывы: