ALDI HS-198 Скачать руководство пользователя страница 1

User Manual

ELECTRIC INFLATOR 

PUMP

ID: #05007

m

yha

nsecontrol.

co

m

M

A

N

UA

DE

VELO

PED IN

GE

RM

A

N

Y

User-friendly

Manual

Содержание HS-198

Страница 1: ...User Manual ELECTRIC INFLATOR PUMP ID 05007 m y hansecontrol c o m M A N U A L DEVELOPED IN G E R M A N Y User friendly Manual ...

Страница 2: ...er manual 5 Explanation of symbols 5 Safety 6 Proper use 6 Safety instructions 6 First use 10 Checking the pump and pack contents 10 Operation 10 Inflating 11 Deflating the air 11 Cleaning 12 Storage 12 Technical data 13 Declaration of conformity 13 Disposal 14 Disposing of the packaging 14 Disposing of the pump 14 Contents ...

Страница 3: ...3 C D B 2 1 3 4 5 A 2 1 3 4 5 ...

Страница 4: ...4 Package contents device parts 1 Air outlet for inflating 2 Air intake for deflating 3 On off switch 4 Power plug 5 Valve adapter ...

Страница 5: ...rd parties please be absolutely sure to include this user manual Explanation of symbols The following symbols and signal words are used in this user manual on the pump or on the packaging WARNING This signal symbol word designates a hazard with moderate risk which may result in death or severe injury if not avoided CAUTION This signal symbol word designates a hazard with low risk that if not avoid...

Страница 6: ... damage caused by improper or incorrect use Safety instructions WARNING Risk of electric shock A faulty electrical installation or excessive mains voltage may result in an electric shock Only connect the pump if the voltage of the socket corresponds to the specification on the rating plate Only connect the pump to an easily accessible socket so that you can quickly disconnect the pump from the pow...

Страница 7: ... the power plug Never use the power cord as a carrying handle Keep the pump power plug and power cord away from open flames and hot surfaces Lay the power cord so that it does not pose a tripping hazard Do not kink the power cord and do not lay it over sharp edges Only use the pump in indoor areas Never use it in wet rooms or in the rain Never store the pump in such a way that it could fall into a...

Страница 8: ... and mental capacities or lack of experience and knowledge e g older children This appliance is not intended for use by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children must not play with the pump Cleaning and user ...

Страница 9: ...n or near hot surfaces e g stove tops etc Ensure that the power cord does not come into contact with hot parts Never expose the pump to high temperatures heaters etc or to the effects of weather rain etc Never fill the pump with liquid Never attempt to clean the pump by submerging it in water and do not use a steam cleaner to clean it Otherwise the pump could become damaged Never place the pump in...

Страница 10: ...dual parts exhibit any damage If this is the case do not use the pump Contact the manufacturer at the service address specified on the warranty card Operation CAUTION Risk of hearing damage Thepumpmaybeloudwhileinoperationandcouldleadtohearing damage Wear ear protection when using it for long periods NOTICE Risk of damage The pump is not designed for long term continuous operation and may overheat...

Страница 11: ... the I position 6 Switch the pump off set the on off switch to the 0 position as soon as the article is fully inflated 7 Remove the valve adapter from the inflated article 8 Place the cap back onto the valve on the inflated article Deflating the air For smaller air valves you may need to squeeze the valve with your fingers so that the safety tab on the valve can open and allow air to pass through ...

Страница 12: ...les or sharp or metallic cleaning utensils such as knives hard scrapers or similar They could damage the surfaces Never place the pump in the dishwasher It would be destroyed as a result 1 Disconnect the power plug before cleaning 2 Let the pump cool off completely 3 Wipe the pump off with a dry cloth Storage All parts must be completely dry before being stored Always store the pump in a dry area ...

Страница 13: ...pter material Colour Product code HS 198 220 240 V 50 60 Hz 150 W approx 2 7 m approx 45 mbar approx 250 l min 22 000 min 1 II ABS PE Red 96351 HS 198A 12 V 75 W approx 3 05 m approx 47 mbar approx 270 l min 18 000 min 1 III ABS PE Black 96351 Declaration of conformity The EU Declaration of conformity can be requested from the address on the enclosed warranty card ...

Страница 14: ...stems of recyclable materials Old appliances may not be disposed of in the household waste Should the pump no longer be capable of being used at some point in time dispose of it in accordance with the regulations in force in your city or county This ensures that old appliances are recycled in a professional manner and also rules out negative consequences for the environment For this reason electri...

Страница 15: ...e within its intended use over the course of the first 3 years after date of purchase we will remedy the problem as quickly as possible once it has been brought to our attention In the unlikely event of such an occurrence or if you require any information about the product please contact us via our helpline support services details of which are to be found both in this manual and on the product it...