background image

USER GUIDE

MODEL NUMBER:
PRPT-00003

Mini Power Post

Pump Connection Center

Содержание Mini Power Post PRPT-00003

Страница 1: ...USER GUIDE MODEL NUMBER PRPT 00003 Mini Power Post Pump Connection Center...

Страница 2: ...Post 4 Features 5 Installation 6 Installing Post 6 7 Wiring 7 8 General Operation 9 Septic Tank Monitoring 9 Alarm Auxiliary with Auto Dialer 10 Troubleshooting 11 Specifications 12 Warranty Informat...

Страница 3: ...s complying with all federal state and local codes regulations and practices This product must be installed by qualified personnel familiar with all applicable local electrical and mechanical codes Re...

Страница 4: ...vel monitoring 6 Pump Float Switch The pump float switch is used to control the pump directly When actuated the pump float switch will pass power to the pump 6 5 4 1 Mini Power Post The Mini Power Pos...

Страница 5: ...on 3 Cable grips Pre installed making it easy to run wire in and out of the enclosure 4 Partition Separates high voltage from low voltage 3 1 6 2 3 4 5 Pump Power Receptacle not shown A female 15A pum...

Страница 6: ...adapter into access hole On the inside of the post use the lock nut 1 to secure the terminal adapter in place use PVC cement to ensure proper bonding between the terminal adapter and post per local co...

Страница 7: ...agram 5 Connect wires coming in Cable Grip A to wires coming in Cable Grip B as shown in the diagram Note NEVER leave ground wire exposed use provided Wago connectors for wire termination Installing P...

Страница 8: ...e take the dirt soil removed and backfill the area you dug for the post and riser Backfill Area Backfill Area STEP 3 INSTALL BOTTOM COVER Place the bottom of enclosure back on lining up with the groov...

Страница 9: ...he pump float switch deactivates the pump should turn off STEP 2 ALARM FLOAT SWITCH Activate the alarm float switch the alarm indicator of the indoor alarm should illuminate and the buzzer should annu...

Страница 10: ...ch The Mini Power Post is installed into the ground and attached to the septic tank riser The pump float switch is only wired to the pump power line When the pump float switch is actuated the pump wil...

Страница 11: ...ed the Versa larm alarm indicator will illuminate the buzzer will annunciate and the auxiliary contacts close activating the input of the auto dialer sending a message to programmed number s The alarm...

Страница 12: ...ne Indoor Alarm 20 Alarm Float and 20 Filter Switch 4 Pump Switch Options piggyback plug models X No Pump Switch Option 1C 13 Amp 15 Medium Angle Pump Switch 2C 13 Amp 15 Wide Angle Pump Switch 4C 13...

Страница 13: ...art Please contact the sales representative in your area to determine the designated Alderon location for return and to obtain the return goods authorization If you do not have a sales representative...

Страница 14: ...14 Alderon Industries Leading Edge Control Products Mini Power Post USER GUIDE This page intentionally left blank...

Страница 15: ...Alderon Industries Leading Edge Control Products 15 Mini Power Post USER GUIDE This page intentionally left blank...

Страница 16: ...awley MN 56549 Main Office Phone 218 483 3034 Website alderonind com General Inquiry Email info alderonind com Submit New Orders orders alderonind com UG00009_Rev06_PRPT 00003_Mini Power Post May 27 2...

Отзывы: