Страница 1: ...USER GUIDE PART NUMBER 7039 Cast Iron Cable Weight Control and Pump Switches...

Страница 2: ...a 8 Testing 8 General Operation 9 Narrow Angle Control or Pump Switch Information 9 Medium Angle Control Switch Information 10 Medium Angle Pump Switch Information 10 Wide Angle Control or Pump Switch...

Страница 3: ...ust be installed by qualified personnel familiar with all applicable local electrical and mechanical codes Refer to the National Electrical Code NFPA 70 Failure to properly install and test this produ...

Страница 4: ...uct Included 1 Cast Iron Cable Weight The cast iron cable weight is used as a pivot point for the desired activation level of the float switch 2 Screws Secures the cast iron cable weight to the float...

Страница 5: ...n 2 Screw Holes Two screw holes are located on the front outside portion of the cable weight 3 Threaded Screw Holes Two threaded screw holes are located on the inside back portion of the cable weight...

Страница 6: ...l place float switch cable in the cable slot on the bottom half of the cable weight while the top half is removed and tether float switch to the appropriate length Refer to the instructions that came...

Страница 7: ...he cable weight over the float switch cable and align the screw holes to the bottom half of the cable weight 3A Tighten the two screws so both halves of the cable weight are snug against the cable 3B...

Страница 8: ...sing a mounted float bracket or per local codes STEP 2 WIRING Wire the float switch per manufacturer s instructions Testing STEP 1 TESTING THE ACTIVATION LEVEL Check the installation of the float swit...

Страница 9: ...oat switches Note Other brands of float switches may have different total operating angles or activation deactivation levels above below horizontal Refer to the instructions that came with the float s...

Страница 10: ...wn empty applications Normally Closed Low Level Alarms or Pump Up fill applications Medium Angle Control Switch Information normally open example normally open example 50 total operating angle Normall...

Страница 11: ...ms or Pump Down empty applications Normally Closed Low Level Alarms or Pump Up fill applications normally open example Multiple float switches with cable weights are typically used for control applica...

Страница 12: ...he bottom half of the cable weight Align the screws holes on the top half of the cable weight with threaded screw holes on the bottom half of the cable weight securely fasten screws Float switch cable...

Страница 13: ...R GUIDE Specifications Cable Weight Material Screws Material Cable Slot Operating Temperature Diameter Height Weight Zinc plated cast iron Stainless steel 18 AWG to 14 AWG type cable sizes diameter 0...

Страница 14: ...or part Please contact the sales representative in your area to determine the designated Alderon location for return and to obtain the return goods authorization If you do not have a sales representat...

Страница 15: ...Alderon Industries Leading Edge Control Products 15 Cast Iron Cable Weight USER GUIDE This page intentionally left blank...

Страница 16: ...Hawley MN 56549 Main Office Phone 218 483 3034 Website alderonind com General Inquiry Email info alderonind com Submit New Orders orders alderonind com UG00078_Rev03_Cast Iron Cable Weight August 27 2...