27 — Loopbacks
2902 MainStreet Technical Practices
27-15
May 2002 90-2906-01
Figure 27-16 Loopback C for primary rate circuits
Procedure 27-6 To set a primary rate circuit loopback
where
p
is 1 or 2, and
c
is 1 to 31
27.6
Primary rate link loopbacks
The two types of primary rate link loopbacks—equipment and line—are used to test
end-to-end connections over a primary rate link. When initiated, the entire link is
looped back.
DX
E1 Framer
2902 MainStreet
Control card
E1 G.703,
HDSL or
Optical LIM
9115
DX
UNDO_MAINT
ON_CIRCUIT
<P
p-c
>
↵
LOOPBACK_A
LOOPBACK_C
UNDO_LPK
MAINT
SK000544
Caution —
Initiating a primary rate link loopback causes all calls in
progress on the selected module to be dropped. No new calls can be
initiated on the module while it is looped back. Primary rate
loopbacks should be performed only in extreme cases or when node
traffic is minimal.
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...