26 — System diagnostics
2902 MainStreet Technical Practices
26-9
May 2002 90-2906-01
Figure 26-2 Signaling leads display for a DNIC module
Driving outgoing signaling leads
Each bit of an outgoing signaling lead for a data or primary rate circuit can be driven
to a new state: either 0 (off) or 1 (on).
After you select a new signaling lead state, the system prompt remains on the display,
allowing you to change the signaling lead as many times as you wish.
Any change you enter is temporary; the signaling lead status is overridden if any
normal network signaling is received.
Procedure 26-9 To change outgoing signaling leads
where
pp
is 1 or 9,
c
is A or B
signal
is the signaling lead you wish to change
signal state
is 0 (off) or 1 (on)
2902 MainStreet 82211-ab-cd Alarms:18 No Date 0:12R
Circuit Type Loopback Status Connection
M01-A DNIC None Configured None
Installed Type: 2603 9
Firmware ID : $14
Hardware ID : $2
Feature ID : $1
Status : Ok
INPUTS:
OUTPUTS:
MAINT ON_CIRCUIT 1-A SHOW_SIGNL
1- 2- 3- 4- 5-
6- 7- 8-CANCEL 9-QUIT 0-
<
signal state
>
↵
MAINT — ON_CIRCUIT — <
pp-c
>
↵
— SET_SIGNAL <
signal
>
↵
SK000540
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...