18 — RS-232 DCM
2902 MainStreet Technical Practices
18-7
May 2002 90-2906-01
Stop bits
Stop bits signify the end of a character in asynchronous transmission. The number of
stop bits can be set to:
•
1 bit (default)
•
2 bits
Parity
Parity is an error detection method that adds an extra bit to each transmitted
character. It is based on the number of zeros or ones in each character. Five parity
schemes are supported:
•
no parity (default)
•
odd
•
even
•
mark
•
space
Procedure 18-6 To set the data structure
where
pp
is 1 or 9, and
c
is 1 or 2
* Default
18.9
Clocking (synchronous only)
Synchronous data devices require two clocking signals: one for the receive data
stream and one for the transmit data stream. The receive clock supplies timing for
receive data; the transmit clock supplies timing for transmit data. Transmit data and
receive data are defined relative to the data device configured as DTE; the transmit
clock is used by the DTE device to transmit data and by the DCE device to receive
data. Figure 18-1 shows these relationships.
STOP_BITS
PARITY
CHAR_LEN
8_BITS*
7_BITS
6_BITS
5_BITS
SPACE
NONE*
ODD
MARK
EVEN
2_BITS
1_BIT*
CONFIG — CIRCUIT — <
pp-c
>
↵
— FUNCTION
SK000499
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...