background image

OmniAccess 4324: Installation Guide

8

Part 031640-00

May 2005

Selecting a Location

The Alcatel Wireless LAN Switch, like other network and computing devices, 
requires an “electronics friendly” environment.

z

Reliable power

Verify that your electrical outlet is compatible with the Alcatel Wireless LAN 
Switch. The switch power input is auto-ranging and accepts 90~132/180~264 
VAC, 50 to 60 Hz, 4.0/2.0 A.

The power cords must be rated to 10 A and conform to grounded electrical 
standards in the country where the product is operated.

Use of a power line conditioner or Uninterruptible Power Supply (UPS) can 
decrease or mitigate problems caused by power service fluctuations. Verify that 
the output of any power shaping device is compatible with the Alcatel Wireless 
LAN Switch power supply.

z

Cool, non-condensing ventilation

For proper operation, the Alcatel Wireless LAN Switch requires an environment 
with an ambient air temperature between 0 and 40 ºC (32 to 104 ºF). Humidity 
must be kept at non-condensing levels between 5 and 95%.

Where a large number of electrical devices are working in the same area, 
additional air conditioning or air circulation equipment may be required.

z

Ample space

For proper air circulation, leave at least 10 cm (4 inches) clearance for the vents 
on the left and right of the chassis.

Leave additional space in front and back of the chassis to access power cords, 
network cables, and indicator LEDs.

z

Limited electromagnetic interference

For best operation, keep the Alcatel Wireless LAN Switch and all cords and 
cables at least 0.7 meters (2 feet) from fluorescent lighting fixtures, and 2 
meters (6 feet) from photocopiers, radio transmitters, electric generators, and 
other sources of strong electromagnetic interference.

Содержание Alcatel OmniAccess 4324

Страница 1: ...i OmniAccess 4324 Wireless LAN Switch Installation Guide TM...

Страница 2: ...All rights reserved Specifications in this manual are subject to change without notice Originated in the USA Trademarks AOS W and Alcatel OmniAccess 4324 are trademarks of Alcatel in the United States...

Страница 3: ...tions not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This product complies with Part 15 of the FCC Rules Operation is subject...

Страница 4: ...1 Subchapter J Part 1040 10 and IEC 60825 1 1993 A1 1997 A2 2001 IEC 60825 2 2000 For continued compliance with the above laser safety standards only approved Class 1 modules from our approved vendors...

Страница 5: ...s LAN Solution xi Deployment Summary xii Chapter 1 System Overview 1 Features 1 Physical Description 2 Chapter 2 Installing the Chassis 5 Pre Installation Checklist 5 Precautions 6 Requirements 7 Rack...

Страница 6: ...ay 2005 FE Network Ports 18 Serial Power Over Ethernet 18 Physical Description LEDs 18 Pin Outs 20 Cables 21 GE Uplink Ports 22 Physical Description and LEDs 22 Serial Console Port 25 Port Adapter Pin...

Страница 7: ...l is organized as follows Chapter 1 System Overview Describes the main features of this product including physical diagrams Chapter 2 Installing the Chassis Instructions for mounting the chassis and a...

Страница 8: ...z Filenames software devices and certain commands when mentioned in the text Commands In the command examples this bold font depicts text that the user must type exactly as shown Arguments In the comm...

Страница 9: ...Preface ix Contacting Alcatel Web Site Telephone Numbers z Main Site http www alcatel com z Support http www alcatel com enterprise z Main US Canada 800 995 2612 z Main Outside US 818 880 3500...

Страница 10: ...OmniAccess 4324 Installation Guide x Part 031640 00 May 2005...

Страница 11: ...major components z Alcatel Wireless LAN Switch This is an enterprise class switch into which multiple Access Points APs and Air Moni tors AMs are connected and controlled z Alcatel Wireless Access Poi...

Страница 12: ...ole messages to ensure proper operation The Alcatel Wireless LAN Switch Installation Guides provide the necessary instructions Initial configuration of the Alcatel Wireless LAN Switch Configuration re...

Страница 13: ...nts The following tasks are involved z Configure the planned network features via command line or Web inter face z Test and debug the deployment Refer to the Alcatel AOS W User Guide and the Alcatel A...

Страница 14: ...OmniAccess 4324 Installation Guide xiv Part 031640 00 May 2005...

Страница 15: ...chapters Features This section outlines the general features of the Alcatel Wireless LAN Switch z 24 10 100 Mbps Fast Ethernet FE ports with Serial and Power Over Ethernet SPOE capability z 2 10 100 1...

Страница 16: ...ing wireless APs such as the Alcatel Wireless Access Point as well as wired LAN segments The ports provide 10 100 Mbps Fast Ethernet connectivity and in some cases power and serial connectivity as wel...

Страница 17: ...r See Serial Console Port on page 25 for more port and cable specifications See the Alcatel AOS W User s Guide for details on using the features available through this port Fans heat exhaust on side F...

Страница 18: ...OmniAccess 4324 Installation Guide 4 Part 031640 00 May 2005...

Страница 19: ...screws included Four 12 24 screws included or screws appropriate for your rack Alcatel power cord rated to at least 10 A with IEC320 connec tor included Phillips or cross head screwdriver 19 inch equi...

Страница 20: ...lated This includes any network cables To minimize electrical hazard keep water and other fluids away from the product Comply with electrical grounding standards during all phases of installation and...

Страница 21: ...he rack mounting kit contains the following parts FIGURE 2 1 Rack Mounting Kit NOTE The four 12 24 screws are intended for securing the switch to the rack Some racks require different screws which are...

Страница 22: ...tch power supply z Cool non condensing ventilation For proper operation the Alcatel Wireless LAN Switch requires an environment with an ambient air temperature between 0 and 40 C 32 to 104 F Humidity...

Страница 23: ...witch chassis as shown in Figure 2 2 FIGURE 2 2 Attaching the Rack Mounting Brackets Orient both brackets so that the narrow flange faces the front When placed properly the brackets screw holes will m...

Страница 24: ...and align the brackets mounting holes with the corresponding holes in your rack frame FIGURE 2 3 Mounting the Alcatel Wireless LAN Switch Use a Phillips or cross head screwdriver to secure the switch...

Страница 25: ...learance requirements FIGURE 2 4 Keep Clear Zones For proper air circulation leave at least 10 cm 4 inches clearance for the vents on the left and right of the chassis Leave additional space in front...

Страница 26: ...he POE devices The total power drawn by all connected Power Over Ethernet POE devices must not exceed 200 W total For details see POE Power Requirements on page 15 Attach the power cord to the power i...

Страница 27: ...Check the fans to verify they are working You should be able to feel significant airflow blowing from the chassis vents at each of the three fan positions Check for the appropriate operation indicato...

Страница 28: ...ystem has passed the initial power up test z Connect appropriate network cables see Appendix B on page 13 for port and cable information You are now ready to perform the initial setup as described in...

Страница 29: ...er Over Ethernet POE Make sure that the total POE power required does not exceed 200 W NOTE Recalculate the worksheet numbers whenever devices using POE are connected to or disconnected from the netwo...

Страница 30: ...OmniAccess 4324 Installation Guide 16 Part 031640 00 May 2005...

Страница 31: ...d serial connectivity to compatible devices z 2 Gigabit Ethernet GE ports Used for high bandwidth 10 100 1000 Mbps GE uplink between the Alcatel Wireless LAN Switch and the wired LAN Each port socket...

Страница 32: ...is connected to a network port the port can provide operating power to that device through the connected Ethernet cable This allows APs to be installed in areas where electrical outlets are unavailab...

Страница 33: ...ts own POE LED located at the right side of the port This LED provides the following POE status information TABLE B 1 FE LNK ACT LED Status Description Off No Ethernet link on the port Green An Ethern...

Страница 34: ...ut is not listed in the switch security policies If security policies are enabled clients are not granted access to your network through the unsecured AP Green flashing An air monitor on this port has...

Страница 35: ...tel SPOE adapters are compatible with the following APs z Direct connection to a POE compatible device This requires a 4 or 8 conductor Category 5 UTP Ethernet cable with an RJ 45 male connector A str...

Страница 36: ...the Alcatel Wireless LAN Switch and the wired LAN The port automatically senses and negotiates speed duplex and MDI MDX settings Physical Description and LEDs FIGURE B 3 GE Uplink Ports Each GE port...

Страница 37: ...current information on modules of other types and from other vendors visit our Web site or contact customer support see page xiii Replacing a GBIC FIGURE 3 1 GBIC Removal and Insertion TABLE 3 1 Appr...

Страница 38: ...000BASE SX optical Shortwave 850 nm Cable Connect or Range 62 5 m multimode fiber SC type fiber optic Up to 260 m 850 feet Cable Connect or Range 50 m multimode fiber SC type fiber optic Up to 550 m 1...

Страница 39: ...e shown in Figure B 4 FIGURE B 4 Serial Port To connect the required RS 232 serial cable to a terminal with a DB 9 male port use the included adapter Pin outs are shown in Figure B 5 FIGURE B 5 Serial...

Страница 40: ...OmniAccess 4324 Installation Guide 26 Part 031640 00 May 2005 Communications Settings TABLE B 6 Console Terminal Settings Baud Rate Data Bits Parity Stop Bits Flow Control 9600 8 None 1 None...

Страница 41: ...2 Environmental Specifications Item Specification Temperature Operating 0 to 40 C 32 to 104 F Storage 0 to 50 C 32 to 122 F Humidity 5 to 95 non condensing TABLE C 3 Operational Specifications Item Sp...

Страница 42: ...A VCCI Class A Japan The CE approval mark on back of the product indicates that it meets European Directive 89 336 EEC EN 55022 Class A CISPR 22 Class A EN55024 EN 61000 3 2 EN 61000 3 3 AS NZS 3548...

Страница 43: ...Notes 29 Notes...

Страница 44: ...OmniAccess 4324 Installation Guide 30 Part 031640 00 May 2005...

Отзывы: