Configuring Chassis Slot, IOM, and MDA Parameters
Page 100
7750 SR-12
C
ONFIGURING
C
HASSIS
S
LOT
, IOM,
AND
MDA P
ARAMETERS
After the SF/CPM is installed, chassis slots, IOMs, and MDAs can be preconfigured prior to the
component installation or configured after the components are installed. Each specific slot must
specify an IOM, MDA slot, and MDA type. Ports cannot be configured until the MDA is
configured.
Preprovision components in the following order:
1. Chassis slot number
2. Card type
3. MDA slot number
4. MDA type
5. Ports
C
ONFIGURING
C
HASSIS
S
LOT
AND
IOM P
ARAMETERS
In the
config
context, use the following CLI commands and syntax examples to provision the
chassis slot and IOM:
Command
Example
Step 1
card
slot-number
card 1
Step 2
card-type
card-type
card-type
iom-20g