Type
Message
Location
Additional Information
Action
55
INTERNAL FAULT ON S0
Internal problem detected
on an S0 access following
release message giving
cause as "deactivation of
level 1"
Board location.
Access marker
If the fault
keeps recur-
ring, check
the bus wir-
ing.
58
ISDN BOARD FAULT
A level 1 error was detected
by the board's OBC
Board location.
Access marker
INFO 0 = type of error (not significant)
If the fault
keeps recur-
ring, check
the bus wir-
ing.
72
UNSUCCESSFUL AT-
TEMPT TO PRINT
Message sent by the output
device (printer) after every 5
failed print attempts.
Check the
printer and its
connection
cable.
103
OBC FAULT
Board location.
INFO 0 and 1 = type of fault
200
4070 IO/EO BASE: SLAVE
LINK CONNECTED TO IN-
VALID INTERFACE
Board location.
Interface mark-
er
INFO 0 = interface number invalid
INFO 1 = base station operating status
Check the
cables on the
2nd link in the
base station
201
4070 IO/EO BASE: FRE-
QUENCY REJECTION
Discrepancy between the
number of frequencies con-
figured by the installer and
the number of DECT fre-
quencies processed
Board location.
Interface mark-
er
INFO 0 to 3 = bitmap of frequencies
authorized and in use
For more information, refer to the "In-
stalling 4070 IO/EO base stations", file
in the "Mobility" section.
202
4070 IO/EO BASE: LOSS
OF SYNCHRONIZATION
ON UA LINK 0
Board location.
Interface mark-
er
INFO 0 = link status (0 = link KO; 1 =
link OK)
Check cabling
Replace the
4070 base
station
203
4070 IO/EO BASE: LOSS
OF SYNCHRONIZATION
ON UA LINK 1
Board location.
Interface mark-
er
INFO 0 = link status (0 = link KO; 1 =
link OK)
Check cabling
Replace the
4070 base
station
204
4070 IO/EO BASE: NO
REPLY ON DSP PRESENT
(RESET)
Board location.
Interface mark-
er
205
4070 IO/EO BASE: TRANS-
MISSION ERRORS DE-
TECTED ON SERIAL LINK
TO DSP (RESET)
Board location.