Fiber management installation (optional)
Equipment and cable installation for 1665 Data Multiplexer
(1665 DMX)
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
1 - 2 7
............................................................................................................................................................................................................................................................
Fiber management installation (optional)
Description
This section describes how to install the fiber management pieces that may be shipped
with the bay.
Important!
If fiber management is to be installed, the width of the bay footprint must
be extended by at least 2.5 inches beyond the bay upright on each side. This is
typically done using base fillers.
Comcode numbers are in parentheses next to the part number.
Procedure
........................................................................................................................................................................................................................
1
Locate three spools (
106738156
), one fiber radius control module (
321-1B
), one left fiber
spool bracket (
848919213
) and 3 M4 X 6 bracket mounting screws (
901340059
) for each
shelf being installed.
........................................................................................................................................................................................................................
2
For each spool, put a nylach fastener through the middle. Then insert a pin halfway
through.
Important!
It is very important that the pin is not completely inserted. This will
deform the fastener and prevent it from being assembled to the bracket.
........................................................................................................................................................................................................................
3
Line up the nylach fastener in one of the spools with the large holes on the top arm of the
bracket.
Содержание Data Multiplexer Explore 1665
Страница 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Страница 168: ... 1665 Data Multiplexer 1665 DMX stand alone installation tests I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 250: ... Additional optical tests optional Installation tests 4 6 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 274: ... 1665 Data Multiplexer 1665 DMX ring setup and testing I I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Страница 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...