Configuration Commands
Page 260
7750 SR OS Interface Configuration Guide
plcd —
Reports path loss of codegroup delineation errors. It is applicable only when the value of
xgig is set to WAN.
Default
plcd
traps are not issued
crc
Syntax
crc
{
16
|
32
}
Context
config>port>sonet-sdh>path
Description
A 16 bit CRC can only be configured on an OC-3 channel, all other channel speeds must use a 32 bit
CRC except for the paths configured with encap-type atm at OC3 speed.
Default
16 for OC-3, DS-1, DS-3
32 for OC-12, OC-48, ATM-OC12/3, ATMOC-3, etc.
Note: The CRC default is 32 when the encap-type is set to ATM and also, the default cannot be
changed when the encap-type is set to ATM.
Parameters
16 —
Use 16 bit checksum for the associated port/channel.
32 —
Use 32 bit checksum for the associated port/channel.
encap-type
Syntax
encap-type
{
atm
|
bcp-null
|
bcp-dot1q
|
ipcp
|
ppp-auto
|
frame-relay
|
wan-mirror
|
cisco-hdlc
}
Context
config>port>sonet-sdh>path
Description
This command configures the encapsulation method used to distinguish customer traffic on an access
SONET/SDH channel sub-port.
When the
encap-type
is set to ATM the CRC default cannot be changed.
When the
encap-type
is ATM, ATM sub-layer verification (GR-1248-CORE,
Generic Requirements
for Operations of ATM Network Elements (NEs)
) is automatically enabled. The result of the
verification includes:
• Out of Cell Delineation (OCD) event count. The OCD event count is described in RFC 2515,
Definitions of Managed Objects for ATM Management
. Note that multiple events occurring
within a second will be counted as 1 event for ATM and ASAP MDAs as a result of a hardware
limit.
• Loss of Cell Delineation defect/alarm. The LCD defect/alarm is defined in RFC 2515,
Defini-
tions of Managed Objects for ATM Management
. When a path is in an LCD defect state, the
path’s operational status will be down. When a path exits the LCD state, the path’s operational
status will change to up (assuming nothing else causes the path to stay down). A trap is raised to
indicate the LCD status change. Also a P-RDI is sent to indicate the defect to the remote end.
The
encap-type
is only required when configuring a SONET/SDH path for access mode.
Содержание 7750 SR OS
Страница 6: ...Page 6 7750 SR OS Interface Configuration Guide Table of Contents ...
Страница 8: ...Page 8 7750 SR OS Interface Configuration Guide List of Tables ...
Страница 10: ...Page 10 7750 SR OS Interface Configuration Guide List of Figures ...
Страница 14: ...Preface Page 14 7750 SR OS Interface Configuration Guide ...
Страница 16: ...Getting Started Page 16 7750 SR OS Interface Configuration Guide ...
Страница 184: ...Card MDA and Port Command Reference Page 184 7750 SR OS Interface Configuration Guide ...
Страница 417: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 417 4 5 SAP PVT 1 1 up up A ima2 ...
Страница 429: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 429 Cells 0 0 Unknown VPI VCI Cells 0 A ALA 49 ...
Страница 437: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 437 bundle num 1 256 type ppp ...
Страница 438: ...Debug Commands Page 438 7750 SR OS Interface Configuration Guide ...
Страница 444: ...Index Page 444 7750 SR OS Interface Configuration ...