Interface Configuration
7750 SR OS Interface Configuration Guide
Page 105
Configuring Forwarding Plane Parameters
The following output provides a forwarding plane configuration. The
fp
command is not allowed
on iom-1 or iom-2 types. An error message appears when the command is executed on an
incorrect IOM type:
MINOR: CLI This command is not supported for iom2-20g.
*A:Dut-C# configure card 10
*A:Dut-C>config>card# info
----------------------------------------------
card-type iom3-xp
fp 1
ingress
mcast-path-management
bandwidth-policy "BWP"
no shutdown
exit
exit
exit
mda 1
mda-type m1-10gb
ingress
mcast-path-management
bandwidth-policy "BWP"
no shutdown
exit
exit
exit
mda 2
mda-type m2-10gb-xfp
ingress
mcast-path-management
bandwidth-policy "BWP"
no shutdown
exit
exit
exit
----------------------------------------------
*A:Dut-C>config>card# exit
Содержание 7750 SR OS
Страница 6: ...Page 6 7750 SR OS Interface Configuration Guide Table of Contents ...
Страница 8: ...Page 8 7750 SR OS Interface Configuration Guide List of Tables ...
Страница 10: ...Page 10 7750 SR OS Interface Configuration Guide List of Figures ...
Страница 14: ...Preface Page 14 7750 SR OS Interface Configuration Guide ...
Страница 16: ...Getting Started Page 16 7750 SR OS Interface Configuration Guide ...
Страница 184: ...Card MDA and Port Command Reference Page 184 7750 SR OS Interface Configuration Guide ...
Страница 417: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 417 4 5 SAP PVT 1 1 up up A ima2 ...
Страница 429: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 429 Cells 0 0 Unknown VPI VCI Cells 0 A ALA 49 ...
Страница 437: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 437 bundle num 1 256 type ppp ...
Страница 438: ...Debug Commands Page 438 7750 SR OS Interface Configuration Guide ...
Страница 444: ...Index Page 444 7750 SR OS Interface Configuration ...