![Alcatel-Lucent 7710 SR SONET Скачать руководство пользователя страница 211](http://html1.mh-extra.com/html/alcatel-lucent/7710-sr-sonet/7710-sr-sonet_configuration-manual_2891745211.webp)
Interface Configuration
7710 SR OS Interface Configuration Guide
Page 185
Signal failure (SF) and signal degrade (SD) alarms are not enabled by default on POS interfaces. It is
recommended to change the default alarm notification configuration for POS ports that belong to APS
groups in order to be notified of SF/SD occurrences to be able to interpret the cause for an APS group to
switch the active line.
For path alarms, modify the logical line aps-id in the
configure port aps-id sonet-sdh path
context. For example:
configure port
aps-1
sonet-sdh path report-alarm p-ais
For line alarms, separately, modify the 2 physical ports that are members of the logical aps-id port (the
working and protect lines). APS reacts only to line alarms, not path alarms.
For example:
configure port
1/2/3
sonet-sdh report-alarm lb2er-sd
configure port
1/3/4
sonet-sdh report-alarm lb2er-sd
For example:
A:ALA-48>config>port>aps# info
----------------------------------------------
working-circuit 1/2/3
protect-circuit 1/3/4
----------------------------------------------
A:ALA-48>config>port>aps#
If the SD and SF
rates must be modified, the changes must be performed at the line level on
both the working and protect APS port member.
The
no
form of this command deletes an aps-
group-id
or bundle-aps-group-id. In order for an aps-
group-id
to be deleted,
The same rules apply for physical ports, bundles deletions apply to APS ports/bundles deletions (for
example an aps-group-id must be shutdown, have no service configuration on it, and no path
configuration on it). In addition working and protection circuits must be removed before an aps-group-
id may be removed.
Syntax:
port
aps
-
group-id
aps
:
keyword
group-id
: 1 — 16
Example:
port
aps
-16
ddm-events
Syntax
[
no
]
ddm-events
Context
config>port
Description
This command enables Digital Diagnostic Monitoring (DDM) events for the port.
The
no
form of the command disables DDM events.
Содержание 7710 SR SONET
Страница 6: ...Page 6 7710 SR OS Interface Configuration Guide Table of Contents...
Страница 8: ...Page 8 7710 SR OS Interface Configuration Guide List of Tables...
Страница 10: ...Page 10 7710 SR OS Interface Configuration Guide List of Figures...
Страница 14: ...Preface Page 14 7710 SR OS Interface Configuration Guide...
Страница 16: ...Getting Started Page 16 7710 SR OS Interface Configuration Guide...
Страница 18: ...Page 18 7710 SR OS Interface Configuration Guide Configuration Notes on page 107...
Страница 166: ...Service Management Tasks Page 152 7710 SR OS Interface Configuration Guide...
Страница 354: ...Multi Chassis Redundancy Commands Page 328 7710 SR OS Interface Configuration Guide...
Страница 494: ...Standards and Protocols Page 494 Standards and Protocols...
Страница 496: ...Index Page 496 7710 SR OS Interface Configuration Guide...