Mandatory Regulations
7705 SAR-A Chassis Installation Guide
29
Laser Interface
The equipment uses laser devices that are rated in accordance with IEC 60825-1 as Class 1
devices.
Safety Approval for DC Systems
The DC source for the equipment must meet the requirements of a SELV source as defined
in EN 60950-1. For 60V station battery systems, the source is considered TNV-2 as per
IEC/EN 60950-1 and must have reinforced insulation from the AC mains. High-voltage DC
sources must meet EN 60950-1 hazardous voltage secondary source requirements.
The equipment complies with the following Product Safety specification: EN 60950-1.
Protective Earth
Protective earth is referred to as chassis ground in this document. A green, or green and
yellow, colored earth wire must be connected from the site equivalent of the mains earth
connection to all shelves in accordance with IEE Wiring Regulations (16th edition). This
connection is made via the chassis ground connection (refer to
for
specific instructions on connecting the protective earth). The protective earth is also carried
by the mains plug and socket (for AC systems only).
Eco-Environmental
Packaging Collection and Recovery Requirements
Countries, states, localities, or other jurisdictions may require that systems be established for
the return and/or collection of packaging waste from the consumer, or other end user, or from
the waste stream. Additionally, reuse, recovery, and/or recycling targets for the return and/or
collection of the packaging waste may be established.
For more information regarding collection and recovery of packaging and packaging waste
within specific jurisdictions, please contact the appropriate environmental health and safety
organization.
Содержание 7705 SAR-A
Страница 23: ...Mandatory Regulations 7705 SAR A Chassis Installation Guide 23 Figure 3 Earth ground 9718 ...
Страница 66: ...Installation Site Assessment 66 7705 SAR A Chassis Installation Guide ...
Страница 76: ...Chassis Ground Wiring 76 7705 SAR A Chassis Installation Guide ...
Страница 82: ...Wiring and Connecting DC Power 82 7705 SAR A Chassis Installation Guide ...
Страница 132: ...7705 SAR A Ports 132 7705 SAR A Chassis Installation Guide ...
Страница 154: ... 2015 Alcatel Lucent All rights reserved 3HE 10141 AAAB TQZZA Edition 01 ...