SHDSL Near-end severely ES threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
SDSLNSEScTHR24
Information
The SHDSL near-end severely errored seconds counter exceeded the
provisioned threshold during a 24-hour monitoring period.
Alarm category
Transmission
ASAP
sdsl
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
–
Cause
Severely Degraded connection - More SES than the allowed threshold (20)
have been detected in the current 24-hour bin.
Actions
Check SHDSL connection on attenuation and crosstalk.
Note(s)
The default values of the raise and clear thresholds are fix preset. They cannot
be changed by user provisioning.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-139
Содержание 1643 AM
Страница 346: ......