SHDSL Near-end errored seconds threshold crossing 15-min
...................................................................................................................................................................................................................................
Alarm identifier
SDSLNEScTHR15
Information
The SHDSL near-end errored seconds counter exceeded the provisioned
threshold during a 15-minute monitoring period.
Alarm category
Transmission
ASAP
sdsl
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
–
Cause
Degraded connection - More ES than the allowed threshold (120) have been
detected in the current 15-minutebin.
Actions
Check SHDSL connection on attenuation and crosstalk.
Note(s)
The default values of the raise and clear thresholds are fix preset. They cannot
be changed by user provisioning.
Alarm messages
...................................................................................................................................................................................................................................
1-136
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007
Содержание 1643 AM