SDSL Not expected input signal
...................................................................................................................................................................................................................................
Alarm identifier
SDSLcNES
Information
An incoming SDSL signal detected on a line- or tributary unit which was
provisioned “Not monitored”.
Alarm category
Transmission
ASAP
sdsl
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
–
Cause
There are two possible reasons:
1. Either the port is intentionally not in use, and therefore is provisioned “Not
Monitored”, but mistakenly an input signal is applied (due to erroneous
routing of intermediate cabling for example), or
2. although an input signal is applied, the port is mistakenly provisioned “Not
Monitored”.
Actions
Put the port in “Monitored”- state or check intermediate cabling.
Alarm messages
...................................................................................................................................................................................................................................
1-130
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007