RPSIP 2: <user entered string>
...................................................................................................................................................................................................................................
Alarm identifier
RPSMDcIP2
Information
The Miscellaneous Discrete Input (MDI) number 2, located on the remote
power supply box, indicates an environmental alarm condition.
Alarm category
Environment
ASAP
mdi
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
–
Cause
Alarm condition of co-located equipment.
Actions
The measures to be taken depend on the specific application of the respective
MDI.
Note(s)
MDIs can be used to monitor co-located equipment, a temperature sensor, for
example. MDIs can thus be used to trigger the reporting of application-specific
environmental alarms.
Each MDI can be assigned a descriptive text identifying the type of
environmental alarm condition in more detail.