P12s Network connection server signal fail egress
...................................................................................................................................................................................................................................
Alarm identifier
P12SgcSSF
Information
The 2-Mbit/s connection is unavailable due to faults in the serving section
layer, as indicated by the reception of the alarm indication signal at the higher
order path layer (SDH -> PDH). This can occur when the section layer and
higher order path layer are managed separately.
Alarm category
Transmission
ASAP
pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Cause
One or more VC-12 or MS faults in this or upstream network elements.
Actions
This message is always raised as a consequence of one or more equipment
and/or transmission faults. Clear these alarms first.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-111