P12s Near- end errored seconds threshold crossing 15-min
...................................................................................................................................................................................................................................
Alarm identifier
P12SNEScTHR15
Information
The P12s near-end errored seconds counter exceeded the provisioned threshold
during a 15-minute monitoring period (PDH -> SDH).
Alarm category
Quality of service (performance monitoring)
ASAP
pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
–
Cause
Equipment fault(s) in the upstream station.
Actions
Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................
1-98
Alcatel-Lucent - Proprietary
See notice on first page