Albrecht AE 5890 EU Скачать руководство пользователя страница 1

AE5890 EU ALIGNMENT PROCEDURE 

 

 

     SUPPLY VOLTAGE: 13.8 VDC 
 

1.

 

PLL ALIGNMENT: 

 

VCO (Convert the unit to Full Band Mode: Code 3) 
     CH.1U – 120 to 200mV 
     CH. 40J – 5 to 6 Volts 
     Align T14 (ST306), Test Point: TP3 
 
10.240MHz Frequency Alignment: 
     Test Point: C406 (0 ohm) 
     Clarifier must be at center position 
     Adjust T18 (ST745) to attain frequency reading of 10.240MHz. 
 
Reference Frequency Alignment: 
     Test Point: Between Q68 & C204 

 

 

AM/FM – 10.695MHz adjust T23 

 

 

USB – 10.6925MHz adjust T24 

 

 

LSB – 10.6975MHz adjust T26 

 
Current & Voltage Alignment: 
     Pre amp Current Alignment: 
 

Test Point: CON1, adjust RV15 to 50-80mA 

 
2 Final Amp Voltage Alignment: 
 

Test Point 1: R229, adjust RV12 to 3.5 to 3.9 Volts 

 

Test Point 2: R239, adjust RV11 to 3.5 to 3.9 Volts 

 
 

 

 

2.

 

TRANSMITTER ALIGNMENT: 

 
Audio Generator: 1KHz, 30mV 
Supply: 13.8 VDC 
Full Band: Code 3 
 
At CH.20E adjust T32, T31, T28, T27 & T29 IFT to maximum 
   CH.1E & CH.40E – 18W up FM/SSB 
   CH.1U & CH.40J – 16W up FM/SSB 
   AM: 4 to 12W 
   Adjust RV5 for AM 
   Adjust RV17 for FM 
 
For Code E: 
   CH.1 & 40 – 4W AM/FM adjust RV300 

  

 

 

12W to 15W SSB adjust RV301 

 

Отзывы: