Alba CDVB5 Скачать руководство пользователя страница 3

2

• 

Attempts to repair this will invalidate the warranty.

• 

Refer repairs to this CDVB5 to a qualified service 

personnel only.

• 

Do not disassemble this CDVB5.

• 

There are dangerous-voltage parts inside that 

may cause electric shock even after power is 

disconnected.

• 

Store your CDVB5 in a clean, dry environment.

• 

Unplug the CDVB5 immediately if it gets wet, and 

consult a servicing technician.

• 

Always unplug the CDVB5 before cleaning it.

• 

Wipe dust off the cabinet of the CDVB5 with a clean, 

dry and soft cloth.

• 

Do not place any objects on top of the CDVB5.

• 

Avoid exposing your CDVB5 directly to sunlight or 

other heat sources.

• 

Put your CDVB5 in a well-ventilated area away from 

high humidity.

• 

Do not expose this CDVB5 to rain or moisture, 

dripping or splashing.

• 

For stubborn stains use a damp (not dripping) cloth.

• 

Do not use any cleaning solutions on this CDVB5.

Safety Tips

If smoke, abnormal noise or odour comes out of the

CDVB5, unplug from the mains supply immediately and

contact the retailer. Never try to repair the CDVB5 on

your own. Always contact the dealer.

NOTE: 

This manual contains for-reference-only graphics

and information that are subject to change without notice.

EN 060065

As per the EN 60065 norm requirements, please pay

particular attention to the following safety guidelines.

Do not obstruct the air vents with objects such as

newspapers, table cloths, curtains etc.

Allow at least 5 cm around the product to allow enough 

ventilation.

Do not place the product on or near flammable objects

such as lit candles. The device may not be exposed to

dripping or splashing and no object filled with liquid, such 

as vases, must be put on the device. If the mains power 

supply is used as the on / off control, it must be easily 

accessible.

Please respect the environment and the law : do not throw 

batteries with the household rubbish ; take them back to 

your retailer and dispose of them in the correct container.

Important –

 Please read these instructions fully before installation

Safety Warning

Safety Warning

        Safety Information

Electrical Information

This CDVB5 is fitted with a BS1363/A 13 amp plug.

If it is not suitable for your supply sockets it must be 

removed and replaced with an appropriate plug. If the plug

becomes damaged and/or needs to be replaced please

follow the wiring instructions below. The plug removed

must be disposed of immediately. It must not be plugged 

into a supply socket as this will be an electrical hazard.

If the fuse needs to be replaced it must be of the same 

rating and ASTA approved to BS1362. If the plug is 

changed, a fuse of the appropriate rating must be fitted in 

the plug, adapter or at the distribution board. If the fuse in 

a moulded plug is replaced, the fuse cover must be refitted 

before the appliance can be used.

2-Core plug

 WARNING: 

Do not connect either wire to the earth 

terminal.

This symbol indicates that this 2-core appliance is 

Class II and does not require an earth connection.

CAUTION:

 Dangerous voltages exist inside this unit. Do not 

remove cover (or back). no user serviceable parts inside refer 

servicing to qualified service personnel. Disconnect from 

mains supply when not in use.

The wires in this mains lead are coloured in accordance with 

the following wiring codes:

Blue........................................................Neutral

Brown..........................................................Live

The wires in this mains lead must be connected to the termi-

nals in the plug as follows:

Blue Wire...........................................N or Black

Brown Wire...........................................L or Red

Only a 3 Amp fuse should be fitted in the plug.

WARNING:

 Under no circumstances must the live or neutral 

wires be connected to the earth terminal in a 3- pin mains 

plug.

E

L

N

BLUE TO 

NEUTRAL

BROWN

TO LIVE
CORD 

GRIP

FUSE

Содержание CDVB5

Страница 1: ...ead these instructions fully before installing or using These instructions contain important information which will help you get the best from your appliance and ensure safe and correct installation u...

Страница 2: ...banner 6 Quick station select menu 6 Last program recall 6 Audio language selection 6 Electronic program guide 7 Wake up timer 7 Digital TV 7 Channel manager 8 Channel organiser 8 Channel sorting 9 Ch...

Страница 3: ...rol it must be easily accessible Please respect the environment and the law do not throw batteries with the household rubbish take them back to your retailer and dispose of them in the correct contain...

Страница 4: ...EXIT CH CH VOL ENTER VOL FAV DEL MOVE LOCK DAILY P INFO TIMER POWER 7 8 9 25 27 29 30 10 12 15 18 16 14 13 17 11 28 26 24 23 22 21 31 33 19 20 34 35 32 1 3 4 5 6 2 MAIN UNIT 1 Remote sensor 2 LED ind...

Страница 5: ...l lead out of the TV and connect it to the ANT IN connector on the back panel of the CDVB5 4 Connect a scart connector at each end not supplied between the SCART TV socket on the back panel of the CDV...

Страница 6: ...he following screen 2 Use the buttons to navigate up or down and the buttons to change the options 3 When complete press the ENTER button You will be asked if you want to complete the installation Use...

Страница 7: ...button again Audio language selection When viewing a station pressing the LANG button on the remote will display the language selection screen The info banner can be accessed when your are watching a...

Страница 8: ...ogram Press EXIT to return to the EPG User Instructions Audio language selection Wake up timer 1 The wakeup timer function can be activated from the EPG menu Highlight the program you wish to use as t...

Страница 9: ...is possible to re arrange the order channels are displayed in the EPG 1 Use the buttons to scroll through the list of available channels 2 When selected press the YELLOW button to activate the move fu...

Страница 10: ...nstructions require the 4 digit pass code Rename a channel 1 Press either to rename the selected channel 2 Use the numeric keypad to assign a new name Press each number repeatedly to cycle through the...

Страница 11: ...s code is required to proceed with this function The default code is 0000 3 Once the pass code has been entered you will have a choice of All TV Channels or All Radio Channels Press ENTER to make the...

Страница 12: ...y the saturation level setting System Settings EQ Setup The sound can be altered with EQ presets Use the buttons to cycle through the options of Standard Classic Rock Jazz Pop Surround The surround se...

Страница 13: ...out to start or for timer recording to a PVR or VCR device Timer NO This allows you to set up to 8 wake up timers Timer Mode Set to OFF ONCE DAILY WEEKLY or YEARLY Wakeup Mode Select from OFF MESSAGE...

Страница 14: ...nitial option is to enter the existing pass code if you have not changed it enter the following 0000 2 Next enter your new pass code 3 Enter the new pass code again to ensure you entered the correct c...

Страница 15: ...socket Check cable connections in both the TV unit No Signal Is the aerial installation working The aerial cable may not be connected The transmission signal may not be broadcasting The program setup...

Страница 16: ...t should be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential ne...

Страница 17: ...does not cover accidental damage misuse cabinet parts knobs or consumable items y The product must be correctly installed and operated in accordance with the instructions contained in this manual y It...

Отзывы: