INSTALL WITH MINIMUM CLEARANCE TO WALL AS SHOWN (IN INCHES)

A= 24

" Unshielded

     6" Shielded

B= 24

" Unshielded

     6" Shielded

FLOOR PROTECTOR

STOVE

8"

8"

8"

16"

USE APPROVED PROTECTOR

STOVE

*6"

14"

A

B

FRONT

*Alaska pipe shield and rear stove shield

kit is required for 6" clearance from stove

pipe to rear combustible wall.

*Side and rear shields are

required for 12

corner clearance

STOVE

*12"

*12"

ALASKA KODIAK - LIMITED WARRANTY

This warranty applies only to the original purchaser.

Purchase must be made through an authorized Alaska Co.
dealer or a representative of the Alaska Co.

Workmanship is warranted for 5 years from the date of

purchase. The grate system, load view mechanism, cast iron
door and aggregate tile are warranted for 2 years.

Warranty does not apply if damage occurs because of

accident, improper handling or operation, abuse, misuse,
rust or corrosion. No unauthorized repair should be made
or attempted.

Glass and ash pans are not warranted. Optional blower is

warranted for 1 year from date of purchase.

Freight and labor costs incurred or any authorized,

warranted item are the responsibility of the original
purchaser. All warranty claims must be accompanied by
a copy of the original sales agreement.

To make claims under this warranty. Contact the

dealer from whom you purchased this unit.

In the event the unit must be returned to the factory for

inspection or repairs, the original purchaser must ship
prepaid to:

Alaska Co., 3126 Columbia Blvd.
Bloomsburg, PA 17815

In order for this limited warranty to be effective and

binding upon Alaska Co. the following section must be
detached, completed and sent by the original owner to
Alaska Co., 3162 Columbia Blvd., Bloomsburg, PA 17815
within 30 days of purchase.

***All liability for any consequential damages from breach of any written or implied
warranties is disclaimed and excluded here from. Some states do not allow the
exclusion or limitations of accidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which
vary from state to state. This warranty is void if you do not return the attached card
within thirty (30) days after the date of purchase.
***A term required by Federal Law.

Chimney type: Minimum 6 inch diameter approved
low heat residential type all fuel. Chimney Connector:
6 inch diameter 24 gauge blue or black steel. Install at
least 6 inches from wall and 16 inches from ceiling.
Special methods are required when passing through a
wall or ceiling. See instructions and building codes.

Name:

Address:

City:

State:

Zip:

Dealer Name:

Purchase Date:

Serial # (from label):

Phone:

Warranty Registration, Cut here and return to: Alaska Company, Inc., 3162 Columbia Blvd., Bloomsburg, PA 17815

CONAM Inspection, Inc. Auburn, MA 01501 STL - 002

Tested 4/98 to ANSI/UL 1482

FREESTANDING MODE

PREVENT HOUSE FIRES: INSTALL AND USE ONLY IN ACCORDANCE WITH

THE MANUFACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES

U.S. ENVIRONMENTAL PROTECTION AGENCY

THIS HEATER IS ONE FOR BURNING COAL. USE OF ANY OTHER SOLID

FUEL EXCEPT FOR COAL IGNITION PURPOSES IS A 

VIOLATION OF FEDERAL LAW.

CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIAL

S

 ABOUT

RE

S

TRICTION

S

 AND IN

S

TALLATION IN

S

PECTION IN YOUR AREA.

Содержание kodiak

Страница 1: ...can create lethal doses of carbon monoxide gas This gas has no odor or color Purchase a gas alarm for detection Have your chimney cleaned professionally before burning any coal stove Stove doors shoul...

Страница 2: ...Any other cleaning product should be used according to the manufacturers instruction READ ENTIRE MANUAL Read this page before installing your stove STEP 1 Place stove on hearth See last page of this...

Страница 3: ...bolts with tabs B Locate View Glass and Gasket place gasket material around entire outside edge of glass Insert glass into back slotted area of view door reattach bolts with tabs Do not over tighten...

Страница 4: ...edure burn a small fie for one day slowly increase the fire over the next 3 4 days This procedure will allow your firebrick and grate to cure prolonging their durability Starting a Fire A Locate the S...

Страница 5: ...ls wide open for 15 20 minutes This allows your fire to build Once you have a good fire base adjust your draft controls to regulate your temperature range STEP 6 Raking the Fire A Locate the Shaker Ha...

Страница 6: ...Blocked Poor Draft Door s Open Clean Chimney and Pipe Consult a Professional Chimney Sweep Close Doors 1 Good quality coal will result in less ash and more heat 2 The back legs of your stove are threa...

Страница 7: ...1 Ash Door 17 4 Adhesive Backed Channel Gasket 18 1 View Door 19 1 View Glass 20 3 5 Adhesive Backed Channel Gasket 21 4 Adhesive Backed Channel Gasket 22 4 1 1 2 x 5 16 View Ash Door Hinge 23 1 Stov...

Страница 8: ...ctive and binding upon Alaska Co the following section must be detached completed and sent by the original owner to Alaska Co 3162 Columbia Blvd Bloomsburg PA 17815 within 30 days of purchase All liab...

Отзывы: