Erase All Programming 

Restore the "out of box" factory condition. 

 

1.   At the back of the lock, remove the lock housing screw and remove the cover.   
2.   Take out battery pack and remove battery power by disconnecting the battery pack plug. 
3.  With battery power disconnected, short the two white wires (

Remote Input 

wires) together for 10 

seconds to ensure discharge of all capacitors.  After 10 seconds, remove the short.   

4.   Plug in the (provided) male shunt connector into the yellow wire female connector. 
5.  With shunt connector connected, re-connect the battery pack.  The lock will immediately sound 3 

short beeps (if these 3 beeps are not heard, then restart at step 3).    

6.   The lock will then sound more slow beeps, 1 beep for every second it takes to clear the memory.   
7.   Lock is ready for programming after 2 rapid beeps are heard and 2 green LED flashes are seen. 

Verifying Proximity Card and Keyfob Access

 

Test by simply presenting a valid proximity card or fob to the reader in front of the lock. 

VALID CARD - 

Green LED flashes, the sounder beeps several times and the PL6100 unlocks.   

INVALID CARD -

 Red LED flashes several times and the sounder beeps several times.   

Testing the Cards Entered 

Use when re-applying power to a lock already in use (you wish to retain the Lock Program), such as when 
moving an existing lock to a new door.  The lock must be dismantled and powered down for an extended 
period. 

1. Disconnect battery pack connector. 
2. With battery power disconnected, short the two white wires (

Remote Input 

wires) together for 10 

seconds to ensure discharge of all capacitors. 

3. Re-connect battery pack (lock will sound 3 short beeps).  If these 3 beeps are not heard, then restart 

at step 1.  The lock will perform several self tests; when complete, 7 beeps and LED flashes will 
sound.  The lock is now ready for use. 

Power Up--Retain Existing Programming 

ACTIVITY 

LED 

SOUNDER 

COMMENTS 

Access Granted or  

Remote Release 

2 Green Flashes 

2 Beeps 

 

Invalid Card / Fob 

7 Red Flashes 

7 Beeps 

An invalid proximity card / fob does not exist in the Lock 
Program memory. 

Valid but Disabled  

Card / Fob 

1 Green, 4 Red Flashes 

1 Long, 5 Short Beeps 

A proximity card / fob exists in the firmware, but is disabled. 

Emergency Commands 

are in effect  

1 RED Flash every  

two seconds 

-- 

-- 

Low Battery 

See page 8 ("Battery Replacement") before changing  

batteries.  ("Pass Time" is the duration the lock remains 

unlocked after access is granted). 

Red LED and Sounder turn on steady for the  

duration of the "Pass Time". 

LED and Sounder Indicators 

With a fully charged battery, the LED and sounder provide visual and audible feedback as follows: 

Содержание Wireless Trilogy Networx PL6100

Страница 1: ...Access Control System with ProxCard Access 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Note Technical Service is for locksmiths and alarm professionals only Publicly traded on NASDAQ Symbol NSSC PL6100 AL PRE PROXCARD READER ENROLLER PROXKEY KEYFOB HID HID HID CORPORATION PROXCARD ...

Страница 2: ... compatible ProxCard reader In addition data can be retrieved from the lock to your PC with DL Windows soft ware Its real time clock calendar automatically adjusts for Daylight Saving Time and allows for automated programming of events PL6100 WIRELESS LOCK PL6100 Wireless PL Series Lock Features 3 Supported Products 4 Lock Design Overview 5 Terminology Used in this Manual 6 7 Wiring 8 First Time P...

Страница 3: ...isable Groups see page 7 for definition of Group Real time clock and calendar User Access Methods ProxCard and ProxKey Keyfob Batch Enroll Quickly and easily enroll multiple ProxCards and ProxKey keyfobs without the use of a PC Note ProxCards and ProxKey Keyfobs both function identically User Features 5000 Users Service Card One Time Only access see page 7 for User 297 definition Guard Tour see pa...

Страница 4: ...as a LAN or corporate Intranet A Windows PC connected to this network can control and program all PL6100 locks by the use of the DL Window software see OI237 and OI352 With access rights to the software one computer or several can control the software and consequently can control the devices in the system Several Gateway device models are available Wireless Wired AL IM80211 Hardwired Wireless Gate...

Страница 5: ... needing to be in hand One additional advantage is that proximity cards and fobs cannot be duplicated unlike ordinary metal keys Preparing to Program your Lock As the PL6100 does not feature keypad buttons on its housing programming your PL6100 for example adding or deleting proximity cards is allowed only using a PC that is running the computer software application DL Windows The PC must be conne...

Страница 6: ...s to suit the needs of your various installations For exam ple you can program the lock to allow Group 1 Users access ONLY during specific business hours unlock at 9AM lock at noon for lunch unlock at 1PM and lock again at 5PM every weekday In addition DL Windows makes Schedule creation much easier In DL Windows use the Schedule TimeZone screen to first create an individual block of time called a ...

Страница 7: ...e proximity card assigned to User Number 297 pos sesses the unique ability to enable the proximity card assigned to User Number 300 When proximity card 297 is presented to the lock proximity card 300 is en abled for one time use allowing passage for one time only Once used User 300 s proximity card becomes disabled For example you wish to allow one time access to a temporary worker Simply present ...

Страница 8: ...ower Red Black wires External 7 5 VDC Power Source must be used for operation without batteries Remote Input White White wires Wire a normally open contact to wires white and white Momentarily close to allow PL6100 lock to unlock NOTE Remote Input is enabled from the factory Relay COM Orange N O Green N C Yellow Erase Memory Leads Yellow Yellow wires When shunted during power up the Lock Program m...

Страница 9: ... re applying power to a lock already in use you wish to retain the Lock Program such as when moving an existing lock to a new door The lock must be dismantled and powered down for an extended period 1 Disconnect battery pack connector 2 With battery power disconnected short the two white wires Remote Input wires together for 10 seconds to ensure discharge of all capacitors 3 Re connect battery pac...

Страница 10: ...kout Time in Seconds Disabled With other lock models that have keypad buttons this feature is defined as the duration of time the lock refuses to recognize ANY proximity card presentations after the maximum number of invalid entry attempts has been reached valid entries are 1 60 seconds THIS FEATURE DOES NOT APPLY TO PROXIMITY CARD ENTRIES AND THEREFORE IS DISABLED FOR ALL PL6100 LOCKS Lock Respon...

Страница 11: ... been detected Authorized Entry Activates relay anytime a User presents a valid proximity card and is granted access Scheduled Group 1 Activated Activates relay if the PL6100 has been programmed for Scheduled Relay Activation Group 1 Initiated and a member of Group 1 has presented their proximity card within the required window Locked by Schedule Activates relay if the PL6100 has been locked by a ...

Страница 12: ...y card to be pre sented Remote Disables Lock Regardless of the current state of the lock that state will remain unchanged and lock will be disabled for the du ration of Remote Input switch closure Important If this feature is enabled power to the lock MUST be provided from an external power supply Forced Lock Follows Remote When Remote Input switch is closed regardless of the current state of the ...

Страница 13: ...13 User Card Record Sheet NAME OF DOOR DEPARTMENT EMBOSSED NUMBER ON CARD USER NAME LAST FIRST DATE ACTIVATED COMMENTS Page ______ ...

Страница 14: ...ough DL Windows GROUP 1 PUTS UNIT IN PASSAGE A prox imity card previously assigned to Group 1 pre sented to the lock during a pre defined schedule unlocks the lock Programmed only through DL Windows ONE TIME ONLY FOR GROUP 3 USERS If selected in DL Windows allows Group 3 prox imity cards to unlock the door one time only thereafter their proximity card becomes dis abled See OI237 GUARD TOUR Associa...

Страница 15: ...15 NOTES ...

Страница 16: ...or au thorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the prod uct for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the pro...

Отзывы: